Engineered Air HVAC Unit HE100/O

Need answers fast?
Explore the manual using AI.

Engineered Air HVAC Unit HE100/O
Engineered Air HVAC Unit HE100/O

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Engineered Air HVAC Unit HE100/O

Engineered Air HVAC Unit HE100/O

Create an account to install this asset package.

Maintenance Plans for Engineered Air HVAC Unit Model HE100/O

Integrate maintenance plans directly into your work orders in MaintainX.

Ultraviolet Scanner Cleaning

Check mark

Ultraviolet Scanners

Check mark

Wipe the viewing area with a soft cloth dampened with concentrated detergent

Check mark

Check for any remaining contamination on the viewing area

Check mark

Note any issues or observations during cleaning

Check mark

Refer to the UV scanner manufacturers’ literature for additional information

Run this procedureArrow right

1 Yearly Coil Inspection

Check mark

Coils

Check mark

Inspect coils and drain pans for cleanliness and biological growth

Check mark

Clean the external surface of finned coils using a low pressure water spray and a brush

Check mark

Ensure no high pressure steam or water is used for cleaning

Check mark

Verify cleaning additives or solutions are compatible with coil materials or coatings

Check mark

Use a fin comb to straighten any damaged or bent fins

Check mark

Coil Winterization

Check mark

Drain and blow out water coils with compressed air

Check mark

Fill and drain coils several times with appropriate strength pre-mixed inhibited HVAC glycol or other suitable fluid

Run this procedureArrow right

1 Monthly Dodge Ball Bearing Pillow Block Lubrication

Check mark

Lubrication of Dodge Fan Bearings — Ball Bearing Pillow Block

Check mark

Select the shaft diameter and speed (RPM) for lubrication schedule

Check mark

Is it safe to re-lubricate while running?

Check mark

Re-lubricate while running until some purging occurs at seals

Check mark

Adjust lubrication frequency based on purged grease condition

Check mark

Note hours of operation, temperature, and surrounding conditions

Check mark

Is the operation 24 hours?

Check mark

Select the grease type used for lubrication

Check mark

Lubricate bearings prior to extended shutdown or storage

Run this procedureArrow right

1 Yearly Safety Shutoff Valve Testing

Check mark

Safety Shutoff Valve Leak Test

Check mark

De-energize the control system.

Check mark

Close the upstream manual gas valve.

Check mark

Connect a ¼” (6mm) tube to the outlet pressure tap on the safety shutoff valve.

Check mark

Immerse the opposite end of the ¼” (6mm) tube vertically ½” (13mm) into a clear container of water.

Check mark

Count the number of bubbles appearing during a 10 second period.

Check mark

Is the bubble rate greater than that noted in the manufacturer’s table?

Check mark

If the bubble rate is greater than that noted in the manufacturer’s table, repair or replace the valve.

Check mark

If bubble rate is less than noted in the table, remove the ¼” (6mm) tube, reconnect the outlet pressure tap plug.

Run this procedureArrow right

6 Monthly Outdoor Air Intake Inspection

Check mark

Outdoor Air Intakes, Mixing Sections and Dampers

Check mark

Check outdoor air intakes for cleanliness

Check mark

Inspect screens for integrity

Check mark

Verify proper operation of adjacent areas

Check mark

Adjust dampers if required

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Engineered Air

Explore Other Assets