MaintainX Logo
EnterprisePricing
Doosan

Doosan Doosan Generator G290WCU-3B-T3 (C38) G290WCU-3B-T3 (C38)

Need answers fast?
Explore the manual using AI.

Doosan Doosan Generator G290WCU-3B-T3 (C38) G290WCU-3B-T3 (C38)
Doosan Doosan Generator G290WCU-3B-T3 (C38) G290WCU-3B-T3 (C38)

The Doosan Generator G290WCU-3B-T3 (C38) is a robust industrial generator designed for reliable power generation in various applications. Known for its efficiency and durability, this generator model is ideal for both standby and prime power solutions, ensuring optimal performance in demanding environments.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Doosan Doosan Generator G290WCU-3B-T3 (C38) G290WCU-3B-T3 (C38)

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Doosan Doosan Generator G290WCU-3B-T3 (C38) G290WCU-3B-T3 (C38)

Doosan Doosan Generator G290WCU-3B-T3 (C38) G290WCU-3B-T3 (C38)

Create an account to install this asset package.

Maintenance Plans for Doosan Doosan Generator G290WCU-3B-T3 (C38) Model G290WCU-3B-T3 (C38)

Integrate maintenance plans directly into your work orders in MaintainX.

250 Hourly / 3 Monthly Engine Maintenance

Check mark

1. Voltage Selector Door Interlock Switch

Check mark

• Every three months or 250 operating hours, the interlock switch should be checked. Running with no electric load, open the VOLTAGE SELECTOR door. This will shutdown the engine and trip the main breaker. To reset, close the door.

Check mark

2. High Containment Fluid Alarm System

Check mark

• The operation of the high containment fluid alarm system should be checked every 3 months or whenever it appears not to be operating properly.

Check mark

• The level switch is located at the lower end of a pipe at the bottom of the containment tank.

Check mark

• Test the switch by unfastening the u-bolts holding the pipe, and then inverting the pipe to allow the switch float to fall.

Check mark

• The “High Containment Level” LED should illuminate. Replace any defective switch.

Check mark

• Drain the containment area using the drain plug at either end of the containment basin.;

Run this procedureArrow right

Voltage Regulator Adjustment

Check mark

With all electric loads disconnected, engine stopped and main breaker turned on, turn VOLTAGE SELECTOR Switch to 277/480V position, and close and latch the VSS door.

Check mark

Voltage POT(P2) on regulator adjusted to full counterclockwise position

Check mark

Voltage POT on control panel adjusted to full clockwise position

Check mark

Unit started

Check mark

Generator frequency at no load on G10 - G40

Check mark

Generator frequency at no load on G60 - G570

Check mark

VOLTAGE OUTPUT MONITOR switch on the control panel set to L1-L2 position

Check mark

Voltage reading on AC voltmeter after adjusting Voltage POT(P2) on the regulator

Check mark

Stability POT(P3) adjusted counter clockwise until the AC volts within ± 1 volt

Run this procedureArrow right

500 Hourly / 3 Monthly Air Cleaner Maintenance

Check mark

Proper maintenance of the air cleaner provides maximum protection against airborne dust.

Check mark

Squeeze the rubber valve (precleaner dirt dump periodically to ensure that it is not clogged).

Check mark

To service the air cleaners, proceed as follows:

Check mark

Remove filter element.

Check mark

Inspect air cleaner housing for any condition that might cause a leak and correct as necessary.

Check mark

Wipe inside of air cleaner housing with a clean, damp cloth to remove any dirt accumulation. This will permit better seal for gasket on filter element.

Check mark

Install element.

Check mark

The air cleaner assembly (housing) should be inspected every 3 months or 500 hours for any leakage paths.

Check mark

Make sure the inlet is free from obstruction.

Run this procedureArrow right

1 Yearly Engine Maintenance

Check mark

Check Engine Shutdown System Switches (setting)

Check mark

Engine Radiator

Check mark

Replenish with a fresh mixture every twelve months

Run this procedureArrow right

1 Daily Engine Check

Check mark

DAILY ENGINE CHECK

Check mark

Check for loose wire routing clamps. Clamps must be secure and properly mounted. Also check wiring for wear, deterioration and vibration abrasion.

Check mark

Check for evidence of arcing around electrical terminals.

Check mark

Check that the grounding circuit is in accordance with the National Electrical Code Article 250-122 and the local code requirements. As a minimum, the copper wire size should be American Wire Gauge 8 (AWG#8) from the grounding terminal, frame, generator and engine block.

Check mark

Check for loose, or frayed wiring insulation or sleeving.

Check mark

Check for water in the fuel filter/water separator unit. Some engines have a translucent bowl for visual indication, and others have a drain valve below the primary element.

Check mark

Clean the air vents of any obstruction or debris.

Check mark

Check Evidence of Arcing around electrical terminals.

Check mark

Check Loose Wire Routing Clamps.

Run this procedureArrow right

Parts for Doosan Doosan Generator G290WCU-3B-T3 (C38) G290WCU-3B-T3 (C38)

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Air Cleaner Element (Engine) Primary

89288971

Protec Eng Fluid - 1 gal

36875938

Engine Fuel Element

22765325

250 Hour Maintenance Kit (without fluids)

44020253

500 Hour Maintenance Kit (& Engine fluids fluids)

44020204

Air Cleaner Element (Engine) Primary

89288971

Protec Eng Fluid - 1 gal

36875938

Engine Fuel Element

22765325

250 Hour Maintenance Kit (without fluids)

44020253

500 Hour Maintenance Kit (& Engine fluids fluids)

44020204

Air Cleaner Element (Engine) Primary

89288971

Protec Eng Fluid - 1 gal

36875938

Engine Fuel Element

22765325

250 Hour Maintenance Kit (without fluids)

44020253

500 Hour Maintenance Kit (& Engine fluids fluids)

44020204

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Doosan

Explore Other Assets