Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Handler CAH030GDCC

Daikin Air Handler CAH030GDCC

Create an account to install this asset package.

Maintenance Plans for Daikin Air Handler Model CAH030GDCC

Integrate maintenance plans directly into your work orders in MaintainX.

2000 Hours Motor Bearings Lubrication

Check mark

CAUTION: Bearing overheating potential. Can damage the equipment. Do not over lubricate bearings. Use only a high grade mineral grease with a 200°F safe operating temperature.

Check mark

NOTE: Direct-Drive Class Il fans that are supplied with TECO motors have double shielded bearings on frame sizes 140T-280T. These bearings are pre-packed with a long life grease and are not regreaseable. Larger frame size TECO motors are regreaseable and follow the same lubrication recommendations as all other motors

Check mark

Motor bearings and ball bearings lubricated

Check mark

Choose the type of lubricant used

Check mark

Enter the amount of lubricant used

Check mark

Motor run for five minutes after lubrication

Check mark

Sign off on the motor bearings lubrication

Run this procedureArrow right

LVP Variable Speed Sheave Maintenance

Check mark

Belt tension slacked off if belts have been installed

Check mark

Setscrews D loosened

Check mark

Capscrews E loosened but not removed

Check mark

Key F removed

Check mark

Pitch diameter adjusted by opening or closing the movable flanges by half or full turns

Check mark

Key F replaced

Check mark

Setscrews D and capscrews E tightened

Check mark

Belt tension readjusted if belts have been installed, or belts installed and tension adjusted if not previously installed

Check mark

All keys are in place and all setscrews and all capscrews are tight before starting the drive

Run this procedureArrow right

Fan Drive Belt Maintenance

Check mark

Warning: Moving belt and fan can cause severe personal injury or death. Always ensure safety measures are in place.

Check mark

Is the belt tension at the lowest tension at which the belt does not slip under peak load conditions?

Check mark

Measure the belt span

Check mark

Measure the force applied to the belt tension checker

Check mark

Does the measured force match the required values?

Check mark

Are the belts free from foreign material that can cause slippage?

Check mark

Is the V-drive inspected on a periodic basis?

Check mark

Is the belt tension adjusted if the belt is slipping?

Check mark

Is belt dressing avoided?

Run this procedureArrow right

6 Monthly Air Handler Check

Check mark

Check all moving parts for wear

Check mark

Check bearing collar, sheave, and wheel hub setscrews, sheave capscrews, and bearing hold-down bolts for tightness

Check mark

Annually check and snug all electrical connections

Check mark

Inspect for signs of water damage such as corrosion and repair if necessary

Check mark

Check ground conductor and connection integrity and correct if needed

Run this procedureArrow right

1 Weekly Fan Shaft Bearings Lubrication

Check mark

CAUTION: For safety, stop rotating equipment before lubrication

Check mark

Did you add one half of the recommended amount of lubricant?

Check mark

Start bearing, and run for a few minutes

Check mark

Did you stop the bearing and add the second half of the recommended amount of lubricant?

Check mark

A temperature rise, sometimes 30°F (1°C) after lubrication is normal

Check mark

CAUTION: For best results, specific applications should be monitored regularly and lubrication intervals and amounts adjusted accordingly

Check mark

Type of lubricant used

Check mark

Compatibility of grease is critical. Lubricatable bearings are supplied with grease fittings or zerks for ease of lubrication with hand or automatic grease guns. Always wipe the fitting and grease nozzle clean

Check mark

Lubrication Intervals

Run this procedureArrow right

Parts for Daikin Air Handler CAH030GDCC

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets