The Daikin Air Handler CAH025GDDC is a high-efficiency air handling unit designed for optimal indoor climate control. This model features advanced technology for improved air distribution and energy savings, making it ideal for commercial and industrial applications. Experience reliable performance and enhanced comfort with Daikin's trusted engineering.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Air Handler CAH025GDDC
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
2000 Hours Motor Bearings Lubrication
CAUTION: Bearing overheating potential. Can damage the equipment. Do not over lubricate bearings. Use only a high grade mineral grease with a 200°F safe operating temperature.
NOTE: Direct-Drive Class Il fans that are supplied with TECO motors have double shielded bearings on frame sizes 140T-280T. These bearings are pre-packed with a long life grease and are not regreaseable. Larger frame size TECO motors are regreaseable and follow the same lubrication recommendations as all other motors
Motor bearings and ball bearings lubricated
Upper and lower grease plugs removed and cleaned
Grease fitting inserted into the upper hole and clean grease added with a low pressure gun
Motor run for five minutes before replacing the plugs
Select the lubricant used
Amount of lubricant used (in oz)
Sign off on the motor bearings lubrication
6 Monthly Coil Maintenance
Warning: Cleaning should be performed by qualified personnel
Drain pans in any air conditioning unit may have some moisture
Algae, etc., can grow due to airborne spores and bacteria
Periodic cleaning is necessary to prevent this buildup from plugging the drain and causing the drain pan to overflow
Also, keep the drain pans clean to prevent the spread of disease
Dirt and lint can clog the condensate drain, especially with dirty filters. Inspect twice a year to help avoid overflow
Sign off on the coil maintenance
Coil Maintenance
Winterize Water Coils
Did you clean the drain pan regularly to prevent mold development?
Did you drain all coils as thoroughly as possible?
Did you fill each coil independently with an antifreeze solution using a small circulating pump and again thoroughly drain?
Did you check freezing point of antifreeze before proceeding to next coil?
Remove and Replace Components of Coils
Did you remove the flat head fasteners located along the sides of the panel?
Did you remove the frame channels that run the length of the unit along the top?
Did you remove the fan shaft, motor, and any drive components?
1 Yearly Coil Maintenance
CAUTION: Sharp fin edges are a potential injury hazard. Avoid contact with them
Check coils for cleanliness
To obtain maximum performance, the coil must be clean
Check once a year under normal operating conditions and, if dirty, brush or vacuum clean.
Use a chemical coil cleaner on multiple row coils
Read and follow the chemical cleaner's instructions as some cleaners may contain harsh chemicals
Take care not to damage fins while cleaning.
CAUTION-Fin edges are sharp
LVP Variable Speed Sheave Maintenance
Belt tension slacked off if belts have been installed
Setscrews D loosened
Capscrews E loosened but not removed
Key F removed
Pitch diameter adjusted by opening or closing the movable flanges by half or full turns
Key F replaced
Setscrews D and capscrews E tightened
Belt tension readjusted if belts have been installed, or belts installed and tension adjusted if not previously installed
All keys are in place and all setscrews and all capscrews are tight before starting the drive
Access the parts list for your equipment in MaintainX.
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX