The Daikin Air Handler CAH012GDAM is a high-efficiency air handling unit designed for optimal indoor climate control. This model features advanced technology for reliable performance and energy savings, making it ideal for commercial and industrial applications. Experience superior air quality and comfort with Daikin's trusted engineering.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Air Handler CAH012GDAM
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Coil Maintenance
CAUTION: Sharp fin edges are a potential injury hazard. Avoid contact with them
Check coils for cleanliness
To obtain maximum performance, the coil must be clean
Check once a year under normal operating conditions and, if dirty, brush or vacuum clean.
Use a chemical coil cleaner on multiple row coils
Read and follow the chemical cleaner's instructions as some cleaners may contain harsh chemicals
Take care not to damage fins while cleaning.
CAUTION-Fin edges are sharp
Pitch Key Sheave Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Loosen setscrews B and C in moving parts of sheave and pull out external key E.
Adjust sheave pitch diameter for desired speed, open moving parts by half or full turns from closed position.
Replace external key E and securely tighten setscrews B over key and setscrews C into keyway in fixed half of the sheave.
Put on belts and adjust tension. Do not force belts over grooves.
Make future adjustments by loosening the belt tension and increasing or decreasing the pitch diameter of the sheave by half or full turns as required. Readjust belt tension before starting drive.
To provide the same pitch diameter, adjust both halves of the two-groove sheaves by the same number of turns from closed position.
Verify that all keys are in place and that all se screws are tight before starting drive. Check setscrews and belt tension after 24 hours service.
Sign off on the Pitch Key Sheave Maintenance
LVP Variable Speed Sheave Maintenance
Warning: This procedure requires trained personnel with PPE!
Belt tension slacked off if belts have been installed
Setscrews D loosened
Capscrews E loosened but not removed
Key F removed
NOTE: This key projects a small amount providing a grip for removing
Pitch diameter adjusted by opening or closing the movable flanges by half or full turns
NOTE: Two-groove sheaves are supplied with both grooves set at the same pitch diameter. To provide the same pitch diameter for satisfactory operation, move both movable flanges the same number of turns. Do not open sheaves more than five turns for A belts or six turns for B belts
Key F replaced
2000 Hours Motor Bearings Lubrication
CAUTION: Bearing overheating potential. Can damage the equipment. Do not over lubricate bearings. Use only a high grade mineral grease with a 200°F safe operating temperature.
NOTE: Direct-Drive Class Il fans that are supplied with TECO motors have double shielded bearings on frame sizes 140T-280T. These bearings are pre-packed with a long life grease and are not regreaseable. Larger frame size TECO motors are regreaseable and follow the same lubrication recommendations as all other motors
Motor bearings and ball bearings lubricated
Supply and return fans lubricated
Upper and lower grease plugs removed and cleaned
Grease fitting inserted into the upper hole and clean grease added with a low pressure gun
Motor run for five minutes before replacing the plugs
Choose the lubricant used
Amount of lubricant used (in oz)
1 Weekly Fan Shaft Bearings Lubrication
CAUTION: For safety, stop rotating equipment before lubrication
Equipment stopped for lubrication?
Enter the temperature after lubrication
CAUTION: Monitor specific applications regularly and adjust lubrication intervals and amounts accordingly
Select the type of grease used
Compatibility of grease checked?
Lubrication Intervals:
Select the RPM and temperature range
Select the recommended lubricant
Access the parts list for your equipment in MaintainX.
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX