Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Daikin Air Handler CAH010GDAC
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
MVP Variable Speed Sheave Maintenance
Motor base adjusted forward to release belt tension
Belts removed for easier adjustment
Locking setscrews A in the outer locking ring loosened
Sheave adjusted to desired pitch diameter
Sheave type
Number of turns made on the sheave
Both locking screws A in the outer locking ring tightened
Belts replaced and motor base adjusted to tension the belts properly
No other screws loosened during the adjustment
Fan Drive Maintenance
WARNING: Before servicing fans, lock out and tag out all power to the unit. Fans or belts can cause severe personal injury or death
WARNING: Do not open the hinged access door and screw-fastenerd access panels while the unit is operating. Moving parts and strong suction forces can cause severe personal injury or death
Adjust the fan drive
Replace the variable pitched motor sheave with a properly sized, fixed sheave
Replace the adjustable sheaves with fixed sheaves
Measure the diameter of the V-belt outer surface where it passes around the sheave (pitch diameter)
Calculate fan speed from the motor nameplate rpm
Sign off on the fan drive maintenance
Filter Maintenance
Front Load Filter Replacement
Filters removed from inside the unit
Wire clips rotated to release filters
Clean filters fully seated in the frame
Filter Gauge Cleaning
Pressure drop for installed filters
Typical filter pressure drop for clean filters at rated air flow
Final pressure drop for front loaded filters
Prefilters removed to check the pressure drop of the final filters
Pitch Key Sheave Maintenance
Adjust VM/VP Variable Pitch Key Type Sheaves
Loosen setscrews B and C in moving parts of sheave and pull out external key E
Adjust sheave pitch diameter for desired speed
Replace external key E and securely tighten setscrews B over key and setscrews C into keyway in fixed half of the sheave
Put on belts and adjust tension
Make future adjustments by loosening the belt tension and increasing or decreasing the pitch diameter of the sheave as required
Adjust both halves of the two-groove sheaves by the same number of turns from closed position
Verify that all keys are in place and that all se screws are tight before starting drive
Check setscrews and belt tension after 24 hours service
LVP Variable Speed Sheave Maintenance
Belt tension slacked off if belts have been installed
Setscrews D loosened
Capscrews E loosened but not removed
Key F removed
NOTE: This key projects a small amount providing a grip for removing
Pitch diameter adjusted by opening or closing the movable flanges by half or full turns
NOTE: Two-groove sheaves are supplied with both grooves set at the same pitch diameter. To provide the same pitch diameter for satisfactory operation, move both movable flanges the same number of turns. Do not open sheaves more than five turns for A belts or six turns for B belts
Key F replaced
Setscrews D and capscrews E tightened
Access the parts list for your equipment in MaintainX.
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
Replacement Bulb
205484001
Replacement Bulb
205484101
Replacement Bulb
205484201
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX