Daikin Air Handler CAH005GDAM
Daikin Air Handler CAH005GDAM

The Daikin Air Handler CAH005GDAM is a high-efficiency air handling unit designed for optimal indoor climate control. This model ensures reliable performance and energy savings, making it ideal for commercial and industrial applications. Regular maintenance and quality spare parts are essential for its longevity and efficiency.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Air Handler CAH005GDAM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Handler CAH005GDAM

Daikin Air Handler CAH005GDAM

Create an account to install this asset package.

Maintenance Plans for Daikin Air Handler Model CAH005GDAM

Integrate maintenance plans directly into your work orders in MaintainX.

2000 Hours Motor Bearings Lubrication

Check mark

CAUTION: Bearing overheating potential. Can damage the equipment. Do not over lubricate bearings. Use only a high grade mineral grease with a 200°F safe operating temperature.

Check mark

NOTE: Direct-Drive Class Il fans that are supplied with TECO motors have double shielded bearings on frame sizes 140T-280T. These bearings are pre-packed with a long life grease and are not regreaseable. Larger frame size TECO motors are regreaseable and follow the same lubrication recommendations as all other motors

Check mark

Choose the type of lubricant used

Check mark

Enter the size of the motor

Check mark

Enter the amount of lubricant used

Check mark

Did you clean upper and lower grease plugs?

Check mark

Did you insert a grease fitting into the upper hole and add clean grease with a low pressure gun?

Check mark

Did you run the motor for five minutes before replacing the plugs?

Check mark

Sign off on the motor bearings lubrication

Run this procedureArrow right

MVP Variable Speed Sheave Maintenance

Check mark

Adjust motor base forward to release belt tension

Check mark

Remove the belts for easier adjustment

Check mark

Loosen, but do not remove both of the locking setscrews A in the outer locking ring by using a hex key or torque wrench with a hex bit

Check mark

Adjust sheave to desired pitch diameter by turning the outer locking ring, using a spanner wrench or drift inserted into the three holes that are located 120° apart on the ring

Check mark

Enter the pitch diameter

Check mark

Select the type of sheave

Check mark

Tighten BOTH locking screws A in the outer locking ring before operating the drive. Use a torque wrench and tighten to the value

Check mark

Replace belts and adjust the motor base to tension the belts properly

Check mark

Do not loosen any screws other than the two locking screws A in the outer locking ring when adjusting the sheave pitch. Do not operate the drive until the locking screws have been set to the torque specifications

Run this procedureArrow right

Coil Maintenance

Check mark

Winterize Water Coils

Check mark

Coils cleaned and drained?

Check mark

Freezing point of antifreeze solution

Check mark

Remove and Replace Components of Coils

Check mark

Power to the unit locked out and tagged out?

Check mark

Side or Top Panel removed?

Check mark

Frame Channel removed?

Check mark

Fan Section removed?

Check mark

Fan assembly removed and replaced?

Run this procedureArrow right

6 Monthly Air Handler Check

Check mark

Check all moving parts for wear

Check mark

Check bearing collar, sheave, and wheel hub setscrews, sheave capscrews, and bearing hold-down bolts for tightness

Check mark

Annually check and snug all electrical connections

Check mark

Inspect for signs of water damage such as corrosion and repair if necessary

Check mark

Check ground conductor and connection integrity and correct if needed

Run this procedureArrow right

Fan Drive Belt Maintenance

Check mark

Warning: Moving belt and fan can cause severe personal injury or death. Always use approved equipment and ensure floor surfaces are dry and free of oil or grease.

Check mark

General Rules of Tensioning: The ideal tension is the lowest tension at which the belt does not slip under peak load conditions. Check tension frequently during the first 24 to 48 hours of operation. Over tensioning shortens belt and bearing life. Keep belts free from foreign material that can cause slippage.

Check mark

Measure the belt span

Check mark

Force applied to the belt tension checker

Check mark

Does the measured force match the ideal values?

Check mark

Inspect V-drive on a periodic basis. Adjust tension if the belt is slipping. Do not apply belt dressing. This can damage the belt and cause early failure.

Check mark

Is the belt and fan guards on plenum fan units in place?

Check mark

Is the fan locked and tagged out to prevent accidental start up?

Check mark

Is the filter compartment entered only when the fan is completely stopped?

Run this procedureArrow right

Parts for Daikin Air Handler CAH005GDAM

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Replacement Bulb

205484201

Replacement Bulb

205484101

Replacement Bulb

205484001

Replacement Bulb

205484201

Replacement Bulb

205484101

Replacement Bulb

205484001

Replacement Bulb

205484201

Replacement Bulb

205484101

Replacement Bulb

205484001

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets