MaintainX Asset Hub logo
EnterprisePricing
condair

condair Electrode Steam Humidifier EL20

Need answers fast?
Explore the manual using AI.

condair Electrode Steam Humidifier EL20
condair Electrode Steam Humidifier EL20

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

condair Electrode Steam Humidifier EL20

condair Electrode Steam Humidifier EL20

Create an account to install this asset package.

Maintenance Plans for condair Electrode Steam Humidifier Model EL20

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Electrode Steam Humidifier

Check mark

Fill valve strainer removed and cleaned

Check mark

Fill valve strainer inspected and cleaned, if necessary

Check mark

Steam and condensate hoses in the humidifier inspected for cracks and securely fastened

Check mark

Cracked hoses replaced

Check mark

Water hoses inspected for cracks and securely fastened

Check mark

Cracked water hoses replaced

Check mark

Water filter in the supply line cleaned

Check mark

All cables inspected for damage and insulation breakdown

Check mark

Damaged cables replaced

Run this procedureArrow right

Agent Cleaning

Check mark

Use only the cleaning agents described in the procedures below. Disinfectants may only be used if they do not leave behind toxic residue. Rinse all parts thoroughly with clean tap water after cleaning.

Check mark

Follow all instructions, and observe the safety precautions stated below.

Check mark

CAUTION!

Check mark

Risk of damage to the humidifier components!

Check mark

Do not use solvents, aromatized or halogenized hydrocarbons, or other harsh chemicals for cleaning.;

Run this procedureArrow right

Backup Battery / Fuse Replacement

Check mark

DANGER!

Check mark

Risk of electric shock!

Check mark

The Nortec EL steam humidifier is mains powered. Live parts may be exposed when the door panels are removed. Touching live parts may cause severe injury or even death.

Check mark

Prevention: Shut down the unit as described in "Shutting Down" on page 62 before replacing the backup battery or fuses.

Check mark

CAUTION!

Check mark

Electrostatic discharge (ESD)!

Check mark

The electronic components inside the control cabinet in the humidifier are sensitive to electrostatic discharge (ESD).

Check mark

Prevention: Take appropriate measures to protect the electronic components inside the unit against damage caused by electrostatic discharge (ESD). Refer to ANSI/ESD-S20.20.

Check mark

Only a qualified service technician authorized by the customer should replace the backup battery in the control board and the fuses in the driver board(s).

Run this procedureArrow right

Door Panel Removal

Check mark

Refer to Figure 11 for visual guidance.

Check mark

Turn the captive screw in each door panel counter-clockwise with a screwdriver.

Check mark

Lift up the door panel slightly so that the tabs clear the notches in the cabinet.

Check mark

Carefully remove the panel.

Check mark

Sign off on the door panel removal

Run this procedureArrow right

Drain Valve Removal

Check mark

Refer to Figure 13 for visual guidance.

Check mark

Steam cylinder removed

Check mark

Fill hose disconnected from the drain valve

Check mark

Electrical connectors and ground wire disconnected from the drain valve

Check mark

Two screws securing the drain valve to the cabinet removed

Check mark

O-ring in the drain valve removed and discarded

Check mark

Valve disassembled by loosening the brass nut and removing the solenoid assembly from the valve body

Check mark

Solenoid assembly disassembled and all components cleaned

Check mark

Sign off on the drain valve removal

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from condair

Explore Other Assets