Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Climate Master Heat Pump GRV006AGC10CLTS
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Fan Motors Dry Operation and Amperage Check
Warning: Only trained personnel should perform this check
Fan motor dry operation suspected?
If dry operation is suspected, report to the maintenance team immediately
Enter the amp draw from the serial plate data
Is amp draw no more than 10% greater than indicated on serial plate data?
Sign off on the fan motors dry operation and amperage check
Water Coil Maintenance
Direct ground water applications only
If the system is installed in an area with a known high mineral content (125 P.P.M. or greater) in the water, it is best to establish a periodic maintenance schedule with the owner so the coil can be checked regularly.
Coil Cleaning Procedures
Enter the water flow rate through the unit
All other water loop applications
Generally water coil maintenance is not needed for closed loop systems. However, if the piping is known to have high dirt or debris content, it is best to establish a periodic maintenance schedule with the owner so the water coil can be checked regularly.
Dirty Installations
Open Cooling Towers
Coil Cleaning Procedures
1 Yearly Air Coil Cleaning
CAUTION: Fin edges are sharp. Care must be taken not to damage the aluminum fins while cleaning.
Check the air coil for dirt. If dirty, proceed to next step.
Brush or vacuum clean the air coil.
Check the aluminum fins for damage.
Sign off on the air coil cleaning
Piping System Maintenance
Ensure that electrical power to the unit is disconnected.
Is the supply hose connected directly to the return riser valve using a single length of flexible hose?
Open all air vents. Fill the system with water. DO NOT allow system to overflow.
Is all air bled from the system?
Are all strainers in place?
Start the pumps, and systematically check each vent to ensure that all air is bled from the system.
Is make-up water available?
Adjust makeup water as required to replace the air which was bled from the system. Check and adjust the water/air level in the expansion tank.
Enter the loop temperature
Initial Equipment Inspection
Upon receipt of the equipment, carefully check the shipment against the bill of lading.
All units received?
Packaging of each unit inspected?
Each unit inspected for damage?
Ensure that the carrier makes proper notation of any shortages or damage on all copies of the freight bill and completes a common carrier inspection report.
Note any shortages or damage
Concealed damage not discovered during unloading must be reported to the carrier within 15 days of receipt of shipment. If not filed within 15 days, the freight company can deny the claim without recourse.
Date of reporting concealed damage to the carrier
NOTE: It is the responsibility of the purchaser to file all necessary claims with the carrier. Notify your equipment supplier of all damage within fifteen (15) days of shipment.
Access the parts list for your equipment in MaintainX.
Pressure Switch with 1/4” Internal Flare Connection
39B0005N02
Pressure Switch with 1/4” Internal Flare Connection
39B0005N02
Pressure Switch with 1/4” Internal Flare Connection
39B0005N02
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX