The Caterpillar Excavator 345D is a robust and versatile piece of heavy machinery designed for various construction and excavation tasks. Known for its reliability and efficiency, this model offers advanced hydraulic systems and exceptional digging capabilities, making it a preferred choice for contractors and operators in the industry.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Caterpillar Excavator 345D
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly or 6 Monthly Excavator Maintenance
Battery - Clean
Clean the battery surface with a clean cloth. Keep the terminals clean and keep the terminals coated with petroleum jelly. Install the post cover after you coat the terminal post with petroleum jelly
Battery Hold-Down - Tighten
Tighten the hold-downs for the battery in order to prevent the batteries from moving during machine operation.
Rollover Protective Structure (ROPS) - Inspect
Inspect the ROPS for loose bolts or for damaged bolts. Replace any damaged bolts or missing bolts with original equipment parts only.
• Tighten the M16 bolt (1) to125 ± 20 N·m (92 ± 15 lb ft).
• Tighten the M24 bolt (2) to 425 ± 50 N·m (315 ± 40 lb ft).
Do not straighten the ROPS. Do not repair the ROPS by welding reinforcement plates to the ROPS.
100 Hourly Excavator Maintenance
Hydraulic System Oil Filter (Case Drain) - Replace
1. Open the access door on the right side of the machine.
2. Clean the area in order to keep dirt out of the filter base.
3. Remove the used case drain filter from the filter base.
Note: Dispose of used filters according to local regulations.
4. Clean the filter base.
5. Coat the seal of a new case drain filter with clean hydraulic oil.
6. Install the new case drain filter by hand.
Instructions for the installation of the filter are printed on the side of each Caterpillar spin-on filter. For non-Caterpillar filters, refer to the installation instructions that are provided by the supplier of the filter.
10 Hourly or 1 Daily Excavator Maintenance
Cooling System Coolant Level - Check WARNING:
Personal injury can result from hot coolant, steam and alkali.
At operating temperature, engine coolant is hot and under pressure. The radiator and all lines to heaters or the engine contain hot coolant or steam. Any contact can cause severe burns.
Remove cooling system pressure cap slowly to relieve pressure only when engine is stopped and cooling system pressure cap is cool enough to touch with your bare hand.
Do not attempt to tighten hose connections when the coolant is hot, the hose can come off causing burns.
Cooling System Coolant Additive contains alkali. Avoid contact with skin and eyes.
1. Open the access doors on the left side of the machine
2. Maintain the coolant level between the marks on the coolant reservoir.
Note: Refer to Operation and Maintenance Manual, “General Hazard Information” for information that pertains to containing fluid spillage.
12000 Hourly or 6 Yearly Excavator Maintenance
WARNING: Personal injury can result from hot coolant, steam and alkali.
At operating temperature, engine coolant is hot and under pressure.
Remove cooling system pressure cap slowly to relieve pressure only when engine is stopped and cooling system pressure cap is cool enough to touch with your bare hand.
Do not attempt to tighten hose connections when the coolant is hot, the hose can come off causing burns.
Cooling System Coolant Additive contains alkali. Avoid contact with skin and eyes.
NOTICE: Do not change the coolant until you read and understand the material in the Cooling System Specifications section.
NOTICE: Mixing Extended Life Coolant (ELC) with other products reduces the effectiveness of the coolant and shortens coolant life.
Use only Caterpillar products or commercial products that have passed the Caterpillar EC-1 specifications for premixed or concentrate coolants.
Use only Caterpillar Extender with Caterpillar ELC.
1 Yearly Excavator Maintenance
Cooling System Coolant Sample (Level 2) - Obtain
Refer to Operation and Maintenance Manual, “Cooling System Coolant Sample (Level 1) - Obtain” for the guidelines for proper sampling of the coolant.
Obtain the sample of the coolant as close as possible to the recommended sampling interval. Supplies for collecting samples can be obtained from your Cat dealer.
Sample obtained for Level 2 analysis?
Submit the sample for Level 2 analysis.
For additional information about coolant analysis, refer to Special Publication, SEBU6250, “Caterpillar Machine Fluids Recommendations” or consult your Cat dealer.
Sign off on the coolant sample collection
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX