MaintainX Asset Hub logo
EnterprisePricing
Caterpillar

Caterpillar Excavator 345D

Need answers fast?
Explore the manual using AI.

Caterpillar Excavator 345D
Caterpillar Excavator 345D

The Caterpillar Excavator 345D is a robust and versatile piece of heavy machinery designed for various construction and excavation tasks. Known for its reliability and efficiency, this model offers advanced hydraulic systems and exceptional digging capabilities, making it a preferred choice for contractors and operators in the industry.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Caterpillar Excavator 345D

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Caterpillar Excavator 345D

Caterpillar Excavator 345D

Create an account to install this asset package.

Maintenance Plans for Caterpillar Excavator Model 345D

Integrate maintenance plans directly into your work orders in MaintainX.

1000 Hourly or 6 Monthly Excavator Maintenance

Check mark

Battery - Clean

Check mark

Clean the battery surface with a clean cloth. Keep the terminals clean and keep the terminals coated with petroleum jelly. Install the post cover after you coat the terminal post with petroleum jelly

Check mark

Battery Hold-Down - Tighten

Check mark

Tighten the hold-downs for the battery in order to prevent the batteries from moving during machine operation.

Check mark

Rollover Protective Structure (ROPS) - Inspect

Check mark

Inspect the ROPS for loose bolts or for damaged bolts. Replace any damaged bolts or missing bolts with original equipment parts only.

Check mark

• Tighten the M16 bolt (1) to125 ± 20 N·m (92 ± 15 lb ft).

Check mark

• Tighten the M24 bolt (2) to 425 ± 50 N·m (315 ± 40 lb ft).

Check mark

Do not straighten the ROPS. Do not repair the ROPS by welding reinforcement plates to the ROPS.

Run this procedureArrow right

100 Hourly Excavator Maintenance

Check mark

Hydraulic System Oil Filter (Case Drain) - Replace

Check mark

1. Open the access door on the right side of the machine.

Check mark

2. Clean the area in order to keep dirt out of the filter base.

Check mark

3. Remove the used case drain filter from the filter base.

Check mark

Note: Dispose of used filters according to local regulations.

Check mark

4. Clean the filter base.

Check mark

5. Coat the seal of a new case drain filter with clean hydraulic oil.

Check mark

6. Install the new case drain filter by hand.

Check mark

Instructions for the installation of the filter are printed on the side of each Caterpillar spin-on filter. For non-Caterpillar filters, refer to the installation instructions that are provided by the supplier of the filter.

Run this procedureArrow right

10 Hourly or 1 Daily Excavator Maintenance

Check mark

Cooling System Coolant Level - Check WARNING:

Check mark

Personal injury can result from hot coolant, steam and alkali.

Check mark

At operating temperature, engine coolant is hot and under pressure. The radiator and all lines to heaters or the engine contain hot coolant or steam. Any contact can cause severe burns.

Check mark

Remove cooling system pressure cap slowly to relieve pressure only when engine is stopped and cooling system pressure cap is cool enough to touch with your bare hand.

Check mark

Do not attempt to tighten hose connections when the coolant is hot, the hose can come off causing burns.

Check mark

Cooling System Coolant Additive contains alkali. Avoid contact with skin and eyes.

Check mark

1. Open the access doors on the left side of the machine

Check mark

2. Maintain the coolant level between the marks on the coolant reservoir.

Check mark

Note: Refer to Operation and Maintenance Manual, “General Hazard Information” for information that pertains to containing fluid spillage.

Run this procedureArrow right

12000 Hourly or 6 Yearly Excavator Maintenance

Check mark

WARNING: Personal injury can result from hot coolant, steam and alkali.

Check mark

At operating temperature, engine coolant is hot and under pressure.

Check mark

Remove cooling system pressure cap slowly to relieve pressure only when engine is stopped and cooling system pressure cap is cool enough to touch with your bare hand.

Check mark

Do not attempt to tighten hose connections when the coolant is hot, the hose can come off causing burns.

Check mark

Cooling System Coolant Additive contains alkali. Avoid contact with skin and eyes.

Check mark

NOTICE: Do not change the coolant until you read and understand the material in the Cooling System Specifications section.

Check mark

NOTICE: Mixing Extended Life Coolant (ELC) with other products reduces the effectiveness of the coolant and shortens coolant life.

Check mark

Use only Caterpillar products or commercial products that have passed the Caterpillar EC-1 specifications for premixed or concentrate coolants.

Check mark

Use only Caterpillar Extender with Caterpillar ELC.

Run this procedureArrow right

1 Yearly Excavator Maintenance

Check mark

Cooling System Coolant Sample (Level 2) - Obtain

Check mark

Refer to Operation and Maintenance Manual, “Cooling System Coolant Sample (Level 1) - Obtain” for the guidelines for proper sampling of the coolant.

Check mark

Obtain the sample of the coolant as close as possible to the recommended sampling interval. Supplies for collecting samples can be obtained from your Cat dealer.

Check mark

Sample obtained for Level 2 analysis?

Check mark

Submit the sample for Level 2 analysis.

Check mark

For additional information about coolant analysis, refer to Special Publication, SEBU6250, “Caterpillar Machine Fluids Recommendations” or consult your Cat dealer.

Check mark

Sign off on the coolant sample collection

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Caterpillar

Explore Other Assets