Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Carl Zeiss Microscopy Microscope Primovert
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Microscope Cleaning
Post-Use Care
Cover the instrument with the dust cover after every use.
Ensure the instrument is not exposed to ultraviolet radiation without protection.
Installation Environment
Is the microscope installed in a room with humidity less than 75%?
Protection and Cleaning
Cover open tubes with the dust caps.
Remove dust and loose dirt from visible optical surfaces using appropriate tools.
Remove water-soluble dirt by blowing on it and wiping it off with a cloth.
Microscope Halogen Bulb Replacement
Preparation
Switch off the microscope
Allow for sufficient cool-down time
Remove the plug-in power unit from the socket
Removing the Old Bulb
Press down the clamping lug of the cover and remove the cover from the stand
Loosen both fastening screws of the transmitted-light illuminator by pressing against the spring and turning them 90° clockwise
Pull the transmitted-light illuminator out of the stand
Pull the halogen bulb out of the lamp carrier
Microscope Interpupillary Distance and Viewing Height Adjustment
Interpupillary Distance Adjustment
Rotate the eyepiece tubes symmetrically to adjust interpupillary distance
Viewing Height Adjustment
Swivel the eyepiece tubes upward or downward to adjust viewing height
Ergotube Angle Adjustment
Adjust the tube angle for Primovert with ergotube
Microscope Transmitted-Light Phase Contrast Adjustment
Initial Microscope Setup
Adjust the microscope for brightfield
Select the phase-contrast objective
Condenser and Diaphragm Adjustment
Open the aperture diaphragm completely using the lever on the condenser
Introduce the slider into the condenser for phase stop position
Ensure the slider is in the correct detent position
Illumination Adjustment
Adjust the illumination intensity as needed
Access the parts list for your equipment in MaintainX.
Camera Adapter P95-C 2/3" 0.65x
415500-1810-000
Camera Adapter P95-C 1/2" 0.5x
415500-1811-000
Digital Camera Adapter P95 M37/52x0.75
415500-1812-000
Camera Adapter P95-T2 DSLR 1.6x
415500-1825-000
LD Condenser 0.3, a=72 mm
415510-1701-000
Camera Adapter P95-C 2/3" 0.65x
415500-1810-000
Camera Adapter P95-C 1/2" 0.5x
415500-1811-000
Digital Camera Adapter P95 M37/52x0.75
415500-1812-000
Camera Adapter P95-T2 DSLR 1.6x
415500-1825-000
LD Condenser 0.3, a=72 mm
415510-1701-000
Camera Adapter P95-C 2/3" 0.65x
415500-1810-000
Camera Adapter P95-C 1/2" 0.5x
415500-1811-000
Digital Camera Adapter P95 M37/52x0.75
415500-1812-000
Camera Adapter P95-T2 DSLR 1.6x
415500-1825-000
LD Condenser 0.3, a=72 mm
415510-1701-000
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX