MaintainX Logo
EnterprisePricing
Bunn

Bunn Cold Draft Dispenser NITRON

Need answers fast?
Explore the manual using AI.

Bunn Cold Draft Dispenser NITRON
Bunn Cold Draft Dispenser NITRON

The Bunn Cold Draft Dispenser NITRON is a high-performance beverage dispensing system designed for commercial use. This model ensures optimal carbonation and temperature control, making it ideal for serving cold draft beverages efficiently. Regular maintenance is essential to keep the NITRON operating at peak performance.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Bunn Cold Draft Dispenser NITRON

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Bunn Cold Draft Dispenser NITRON

Bunn Cold Draft Dispenser NITRON

Create an account to install this asset package.

Maintenance Plans for Bunn Cold Draft Dispenser Model NITRON

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Dispenser Connector Cleaning

Check mark

Tools required: 32 oz. (946 ml) minimum empty container

Check mark

Disconnect BIB connector from BIB

Check mark

Place an empty container under the dispensing nozzle(s)

Check mark

Dispense from each station until clear water flows from the dispense nozzle(s)

Check mark

Reconnect all product containers

Check mark

Wipe down the internal compartment of the cabinet

Check mark

Sign off on the dispenser connector cleaning

Run this procedureArrow right

Dispenser Connector Cleaning

Check mark

Tools required: 1 empty container, sanitizer, and clean, empty concentrate container

Check mark

All concentrate removed from the dispenser and stored in a separate refrigerated compartment

Check mark

Clean empty pitcher filled with approximately 64 oz (946 ml) of warm tap water approximately 80°F (26.6°C)

Check mark

BIB connectors disconnected inside the cabinet at the quick disconnect. Sanitizing extension tube installed and BIB connector reconnected

Check mark

White cleaning adapters retrieved and connected to the BIB mating connectors

Check mark

BIB connector placed in pitcher of warm tap water

Check mark

Drip tray removed and an empty 5-gallon bucket placed under the dispense nozzles

Check mark

Dispensed at each station until the stream out of the nozzles runs clear (about 30-60 seconds)

Check mark

BIB connectors removed from the warm water

Run this procedureArrow right

1 Daily Dispenser Product Container Cleaning

Check mark

Tools required: 32 oz. (946 ml) minimum empty container

Check mark

Open dispenser door. Lift up on product containers and remove them from the machine

Check mark

Wipe down the internal compartment of the cabinet and the concentrate container’s inlet adapter(s) area

Check mark

Close the door, place an empty container under the dispensing nozzle(s)

Check mark

Dispense from each station until clear water flows from the dispense nozzle(s)

Check mark

Open dispenser door and reconnect all product containers

Check mark

Sign off on the dispenser product container cleaning

Run this procedureArrow right

1 Daily Dispenser Product Container Parts Cleaning

Check mark

Remove and wash the dispense nozzle(s), Nitro Stout Insert, drip tray and drip tray cover in a mild detergent solution. Rinse thoroughly. Use brush (00674.0000) to clean inside and o-ring area on dispense nozzles

Check mark

Remove Nitro Stout Insert in nitro nozzle for cleaning. Replace before reinstalling nozzle

Check mark

Wipe splash panel, areas around dispense nozzle(s), and refrigerated compartment with a clean, damp cloth

Check mark

Use brush and a mild detergent solution to clean inside dispense area where dispense nozzles are removed. Rinse and wipe thoroughly

Check mark

Sign off on the dispenser product container parts cleaning

Run this procedureArrow right

1 Yearly Dispenser Maintenance

Check mark

Clean Condenser Coils and Air Filter weekly

Check mark

Locate the removable air filter at the back of machine and remove to clean in warm soapy water

Check mark

Use a soft bristle brush to clean the build-up of dirt in the condenser

Check mark

Replace Pump Tubing annually

Check mark

Open dispenser door

Check mark

Remove all product containers and place them in a refrigerated (35-40 degrees F [1.6-4.4 degrees C]) environment. Disconnect all connections to ambient products from the bottle adapter

Check mark

Rinse all dispense stations using steps outlined in 'DAILY RINSE PROCEDURE'

Check mark

Disconnect dispenser from power source

Check mark

Remove the dispense platform cover

Run this procedureArrow right

Parts for Bunn Cold Draft Dispenser NITRON

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Ambient Concentrate Conversion Kit

33699.0002

Refillable Ball Valve Container

39302.0000

Brixing Cup

33095.0000

Booster Pump

41815.1000

Brush

00674.0000

Ambient Concentrate Conversion Kit

33699.0002

Refillable Ball Valve Container

39302.0000

Brixing Cup

33095.0000

Booster Pump

41815.1000

Brush

00674.0000

Ambient Concentrate Conversion Kit

33699.0002

Refillable Ball Valve Container

39302.0000

Brixing Cup

33095.0000

Booster Pump

41815.1000

Brush

00674.0000

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Bunn

Explore Other Assets