Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Bunn Cold Draft Dispenser NITRON
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Dispenser Product Container Parts Cleaning
Remove and wash the dispense nozzle(s), Nitro Stout Insert, drip tray and drip tray cover in a mild detergent solution. Rinse thoroughly. Use brush (00674.0000) to clean inside and o-ring area on dispense nozzles
Remove Nitro Stout Insert in nitro nozzle for cleaning. Replace before reinstalling nozzle
Wipe splash panel, areas around dispense nozzle(s), and refrigerated compartment with a clean, damp cloth
Use brush and a mild detergent solution to clean inside dispense area where dispense nozzles are removed. Rinse and wipe thoroughly
Sign off on the dispenser product container parts cleaning
Dispenser Connector Cleaning
Tools required: 1 empty container, sanitizer, and clean, empty concentrate container
All concentrate removed from the dispenser and stored in a separate refrigerated compartment
Clean empty pitcher filled with approximately 64 oz (946 ml) of warm tap water approximately 80°F (26.6°C)
BIB connectors disconnected inside the cabinet at the quick disconnect. Sanitizing extension tube installed and BIB connector reconnected
White cleaning adapters retrieved and connected to the BIB mating connectors
BIB connector placed in pitcher of warm tap water
Drip tray removed and an empty 5-gallon bucket placed under the dispense nozzles
Dispensed at each station until the stream out of the nozzles runs clear (about 30-60 seconds)
BIB connectors removed from the warm water
Dispenser Product Container Cleaning
Tools required: 1 empty 5-gallon (18.9 L) bucket, sanitizer, and clean, empty concentrate container(s)
Remove all concentrate from the dispenser and store in a separate refrigerated compartment
Fill clean empty concentrate containers with approximately 32 oz (946 ml) of warm tap water at minimum 80°F (26.6 C)
Dispense at each station until the stream out of the nozzles runs clear (about 30 seconds)
Remove each dispense nozzle and Nitro Stout insert. Run under hot tap water to remove excess product build-up
Prepare 2.5 gal. (9.46 L) of sanitizing solution
Place nozzles in a separate container of sanitizing solution and mix thoroughly. Allow the parts to soak for 2 minutes
Clean the dispense nozzle receptacle (dispense valves) with sanitizing solution and a soft bristle brush
Clean the concentrate containers inlet adapters with the sanitizing solution and a soft bristle brush. Discard all remaining sanitizing solution
1 Daily Dispenser Connector Parts Cleaning
Remove and wash the dispense nozzle(s), Nitro Stout Insert, drip tray and drip tray cover in a mild detergent solution. Rinse thoroughly. Use brush (00674.0000) to clean inside and o-ring area on dispense nozzles
Remove Nitro Stout Insert in nitro nozzle for cleaning. Replace before reinstalling nozzle
Wipe splash panel, areas around dispense nozzle(s), and refrigerated compartment with a clean, damp cloth
Use brush and a mild detergent solution to clean inside dispense area where dispense nozzles are removed. Rinse and wipe thoroughly
Sign off on the dispenser connector parts cleaning
1 Daily Dispenser Product Container Cleaning
Tools required: 32 oz. (946 ml) minimum empty container
Open dispenser door. Lift up on product containers and remove them from the machine
Wipe down the internal compartment of the cabinet and the concentrate container’s inlet adapter(s) area
Close the door, place an empty container under the dispensing nozzle(s)
Dispense from each station until clear water flows from the dispense nozzle(s)
Open dispenser door and reconnect all product containers
Sign off on the dispenser product container cleaning
Access the parts list for your equipment in MaintainX.
Refillable Ball Valve Container
39302.0000
Ambient Concentrate Conversion Kit
33699.0002
Brixing Cup
33095.0000
Brush
00674.0000
Booster Pump
41815.1000
Refillable Ball Valve Container
39302.0000
Ambient Concentrate Conversion Kit
33699.0002
Brixing Cup
33095.0000
Brush
00674.0000
Booster Pump
41815.1000
Refillable Ball Valve Container
39302.0000
Ambient Concentrate Conversion Kit
33699.0002
Brixing Cup
33095.0000
Brush
00674.0000
Booster Pump
41815.1000
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX