Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Branson Ultrasonics Ultrasonic Vapor Degreaser B452R
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Separator Cleaning
Warning: Follow local regulations for disposal of residue.
Draining Water From Water Separator
Is the desiccator bag removed?
Open the water separator water drain and collect the discharge into a container.
Is the flow stopped?
Close the drain.
Sign off on the separator cleaning
6 Monthly Pump Lubrication
Lubricate pump motors with machine oil every 6 months.
The vertical air cylinder may occasionally require a few drops of mineral oil to lubricate the seals. Add lubricant if the lift lowers from an intermediate held position.
An air lubricator may be used on the incoming air supply. Oil residues will be discharged from the solenoid valve exhaust ports. The mufflers may be replaced by hoses exhausting to an oil trap to prevent oil accumulations or oil mists within the degreaser enclosure.
The cylinder may be lubricated directly:
• Raise the lift to the fully up position
• Remove the top air hose
• Remove the top exhaust flow control valve
• Place one or two squirts from an oil can into the port
• Replace the flow control valve and air hose
Controller Replacement
Warning: Disconnect the degreaser from electrical power before starting the procedure.
Degreaser disconnected from electrical power?
To replace the control or relay board
All wires transferred to the new board?
Mounting screws removed?
New board replaced and screws reinstalled?
To replace the control board
Voltage Switch (SW1) placed in the 230V position?
Set SW2
Degreaser Cleaning
Boil Down
Is the CONTAMINATION WARNING Indicator lighted but the degreaser has not shut down on B/S TEMP FAULT?
Remove 2-3 inches of solvent from the ultrasonic sump.
Did the degreaser shut down on B/S TEMP FAULT or B/S LEVEL FAULT?
Drain the solvent from the boil sump.
Refill the degreaser using the solvent removed in the first step. Add solvent as required.
Cleanout Procedure
Did you operate the degreaser for at least 4 hours to purify the solvent in the ultrasonic sump?
Did you shut off and lock out electrical power?
Degreaser Inspection
Warning: This inspection requires trained personnel with PPE!
Check all plumbing connections for looseness
Check for dampness or cold spots caused by evaporative cooling
Choose the method used for leak detection
Order number for electronic leak detector if used
Pass the leak detector’s sensor around all plumbing joints and tank seams
Sign off on the degreaser inspection
Access the parts list for your equipment in MaintainX.
Accumulator 5/8 ODF All
CPN-513-013
Adapter TB-D15
CPN-103-109
Adapter TB-Header 16 Pos
CPN-029-011
Arm Lift B452
CPN-657-585
Assy Power Cover (non-slotted)
CPN-246-857
Accumulator 5/8 ODF All
CPN-513-013
Adapter TB-D15
CPN-103-109
Adapter TB-Header 16 Pos
CPN-029-011
Arm Lift B452
CPN-657-585
Assy Power Cover (non-slotted)
CPN-246-857
Accumulator 5/8 ODF All
CPN-513-013
Adapter TB-D15
CPN-103-109
Adapter TB-Header 16 Pos
CPN-029-011
Arm Lift B452
CPN-657-585
Assy Power Cover (non-slotted)
CPN-246-857
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX