MaintainX Asset Hub logo
EnterprisePricing
Branson Ultrasonics

Branson Ultrasonics Ultrasonic Vapor Degreaser B452R

Need answers fast?
Explore the manual using AI.

Branson Ultrasonics Ultrasonic Vapor Degreaser B452R
Branson Ultrasonics Ultrasonic Vapor Degreaser B452R

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Branson Ultrasonics Ultrasonic Vapor Degreaser B452R

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Branson Ultrasonics Ultrasonic Vapor Degreaser B452R

Branson Ultrasonics Ultrasonic Vapor Degreaser B452R

Create an account to install this asset package.

Maintenance Plans for Branson Ultrasonics Ultrasonic Vapor Degreaser Model B452R

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Separator Cleaning

Check mark

Warning: Follow local regulations for disposal of residue.

Check mark

Draining Water From Water Separator

Check mark

Is the desiccator bag removed?

Check mark

Open the water separator water drain and collect the discharge into a container.

Check mark

Is the flow stopped?

Check mark

Close the drain.

Check mark

Sign off on the separator cleaning

Run this procedureArrow right

6 Monthly Pump Lubrication

Check mark

Lubricate pump motors with machine oil every 6 months.

Check mark

The vertical air cylinder may occasionally require a few drops of mineral oil to lubricate the seals. Add lubricant if the lift lowers from an intermediate held position.

Check mark

An air lubricator may be used on the incoming air supply. Oil residues will be discharged from the solenoid valve exhaust ports. The mufflers may be replaced by hoses exhausting to an oil trap to prevent oil accumulations or oil mists within the degreaser enclosure.

Check mark

The cylinder may be lubricated directly:

Check mark

• Raise the lift to the fully up position

Check mark

• Remove the top air hose

Check mark

• Remove the top exhaust flow control valve

Check mark

• Place one or two squirts from an oil can into the port

Check mark

• Replace the flow control valve and air hose

Run this procedureArrow right

Controller Replacement

Check mark

Warning: Disconnect the degreaser from electrical power before starting the procedure.

Check mark

Degreaser disconnected from electrical power?

Check mark

To replace the control or relay board

Check mark

All wires transferred to the new board?

Check mark

Mounting screws removed?

Check mark

New board replaced and screws reinstalled?

Check mark

To replace the control board

Check mark

Voltage Switch (SW1) placed in the 230V position?

Check mark

Set SW2

Run this procedureArrow right

Degreaser Cleaning

Check mark

Boil Down

Check mark

Is the CONTAMINATION WARNING Indicator lighted but the degreaser has not shut down on B/S TEMP FAULT?

Check mark

Remove 2-3 inches of solvent from the ultrasonic sump.

Check mark

Did the degreaser shut down on B/S TEMP FAULT or B/S LEVEL FAULT?

Check mark

Drain the solvent from the boil sump.

Check mark

Refill the degreaser using the solvent removed in the first step. Add solvent as required.

Check mark

Cleanout Procedure

Check mark

Did you operate the degreaser for at least 4 hours to purify the solvent in the ultrasonic sump?

Check mark

Did you shut off and lock out electrical power?

Run this procedureArrow right

Degreaser Inspection

Check mark

Warning: This inspection requires trained personnel with PPE!

Check mark

Check all plumbing connections for looseness

Check mark

Check for dampness or cold spots caused by evaporative cooling

Check mark

Choose the method used for leak detection

Check mark

Order number for electronic leak detector if used

Check mark

Pass the leak detector’s sensor around all plumbing joints and tank seams

Check mark

Sign off on the degreaser inspection

Run this procedureArrow right

Parts for Branson Ultrasonics Ultrasonic Vapor Degreaser B452R

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Accumulator 5/8 ODF All

CPN-513-013

Adapter TB-D15

CPN-103-109

Adapter TB-Header 16 Pos

CPN-029-011

Arm Lift B452

CPN-657-585

Assy Power Cover (non-slotted)

CPN-246-857

Accumulator 5/8 ODF All

CPN-513-013

Adapter TB-D15

CPN-103-109

Adapter TB-Header 16 Pos

CPN-029-011

Arm Lift B452

CPN-657-585

Assy Power Cover (non-slotted)

CPN-246-857

Accumulator 5/8 ODF All

CPN-513-013

Adapter TB-D15

CPN-103-109

Adapter TB-Header 16 Pos

CPN-029-011

Arm Lift B452

CPN-657-585

Assy Power Cover (non-slotted)

CPN-246-857

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Branson Ultrasonics

Explore Other Assets