Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bradford White Water Heater M4TW50T6FSX
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
6 Monthly Burner and Pilot Visual Inspection
Burner Inspection and Air Shutter Adjustment
Ensure inner door and burner components are cool before inspection
Inspect pilot flame for stability
Check that the main burner lights smoothly from pilot
Verify main burner burns with a blue flame with minimal yellow tips
Ensure main burner is free from debris accumulation
Burner Air Shutter Calibration
Cast Iron Burner Air Shutter Adjustment
Ensure safety precautions are taken to prevent personal injury from hot components.
Remove outer jacket door and slide inner door from left to right to open.
Loosen the air shutter nut.
Rotate the air shutter to close the opening in the burner.
Slowly rotate the air shutter open until flame becomes as blue as possible with a minimum of yellow tips.
Tighten the air shutter nut.
Is the flame blue with a minimum of yellow tips?
Check for noisy burner operation or soot formation.
Blower Temperature Switch Testing
Blower Temperature Switch Testing
Position power switch on gas control to the “OFF” position.
Remove the three screws from control access cover on blower and remove cover.
Locate blower temperature switch.
Cool switch to below 130°F.
Is there continuity between the switch terminals using a multi-meter set to the ohms setting?
If no continuity, replace switch.
Reconnect wire leads and observe heater operation. Do exhaust gas temperatures rise to or above 165°F?
If exhaust gas temperatures rise to or above 165°F, do switch contacts open?
Simulated Resistive Device Testing
Simulated Resistive Device Testing
Position power switch on gas control to the “OFF” position.
Disconnect simulated resistive device from gas control.
Enter the resistance of the simulated resistive device (in ohms).
Is the resistance within 25,000 ohms and 45,000 ohms?
Replace simulated resistive device if resistance is outside the acceptable range.
Burner Cleaning
Burner Cleaning
Position gas control power switch to the “OFF” position and unplug heater from wall outlet.
Turn off gas supply to water heater.
Remove outer jacket door and slide inner door open from left to right.
Disconnect pilot tube (7/16 wrench) and feedline (¾ wrench) from gas control.
Disconnect igniter/flame sensor wire from gas control.
Remove burner assembly from combustion chamber.
Thoroughly inspect burner surface area and burner port area and remove any loose debris.
For cast iron burners, inspect for any debris build up inside burner casting.
Access the parts list for your equipment in MaintainX.
Gas Control Service Tool
239-45991-00
Gas Control Service Tool
239-45991-00
Gas Control Service Tool
239-45991-00
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX