Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bakers Pride Gas Deck Oven 3151
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Automatic Timer Inspection
Pre-Inspection Checks
Ensure the pilot light is lit
Verify connections
Timer Functionality Test
Is the timer set to the correct time?
Does the timer turn the main burner on at the set time?
Manual Operation Test
Can the main burner be lit manually by turning the timer switch to 'ON'?
Safety and Compliance
Gas Pressure Adjustment
Preparation
Ensure all appliances on the same gas supply line are running at their highest burner setting.
Locate the pressure tap in the control compartment along the gas supply piping.
Pressure Measurement
Connect a manometer to the pressure tap and record the gas pressure.
Is the gas pressure matching the oven’s rating plate?
Adjustment
Select the type of valve equipped in the oven.
If equipped with a 7000 combination valve, adjust the screw on the front of the valve to match the gas supply.
By-Pass Flame Adjustment
Set the temperature dial to 300°
Wait for the oven temperature to rise and remain constant, then turn the dial to the lowest setting
Confirm the main valve is closed
Remove the knob from the thermostat body
Adjust the by-pass flame using the upper screw marked 'B'
Turn the screw counter-clockwise to increase the flame height
Turn the screw clockwise to reduce the flame height
Ensure the flame maintains a minimal height along the burners
Replace the dial and test the temperature settings
Pilot Lighting and Adjustment
Initial Setup
Turn the gas supply to the oven ON
Slightly depress and turn the combination gas cock knob to the PILOT position
Lighting the Pilot
Depress the dial or the red button and hold
Apply a flame to the pilot burner to light
Did the pilot flame stay lit after releasing the dial/button?
Repeat the lighting steps if the pilot flame goes out
Flame Adjustment
Gas Conversion Maintenance
WARNING: Qualified Service Agency Required
Confirm the qualified service agency details
Shut off the gas to the oven
Regulator Replacement
Remove the two screws holding the regulator in place
Remove the old gasket
Install a new gasket and the new regulator
Ensure the regulator gasket is correctly placed with two circular cut-outs over small posts in the valve body casting
Evenly tighten the two screws holding the regulator in place
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX