MaintainX, an Autodesk company
EnterprisePricing
Avantco

Avantco Floor Fryer FF300-N

Need answers fast?
Explore the manual using AI.

Avantco Floor Fryer FF300-N
Avantco Floor Fryer FF300-N

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Avantco Floor Fryer FF300-N

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Avantco Floor Fryer FF300-N

Avantco Floor Fryer FF300-N

Create an account to install this asset package.

Maintenance Plans for Avantco Floor Fryer Model FF300-N

Integrate maintenance plans directly into your work orders in MaintainX.

Thermostat Maintenance

Check mark

NOTICE: Warranty and Liability

Check mark

Ensure service work is performed by a qualified technician

Check mark

Use only approved Avantco replacement parts

Check mark

WARNING: Qualified Technician Required

Check mark

Confirm adjustments and service work are performed by a qualified technician

Check mark

Temperature Check and Calibration

Check mark

Use a reliable temperature test instrument

Check mark

Record the temperature in the center of the frypot

Check mark

Is the temperature stable and identical across readings?

Run this procedureArrow right

Main Burner Maintenance

Check mark

Pre-Maintenance Checks

Check mark

Is the technician qualified and experienced in commercial gas cooking equipment maintenance?

Check mark

Are only approved Avantco replacement parts being used?

Check mark

Main Burner Inspection

Check mark

Measure the length of the inner cone of the flame from each port

Check mark

Does the main burner flame burn with a steady blue flame?

Check mark

Does the flame from each main burner enter each heat tube without touching the front of the frypot or the sides, top, or bottom of each tube?

Check mark

Post-Maintenance Verification

Check mark

Was the maintenance performed by a qualified technician?

Run this procedureArrow right

Auto Safety Pilot Maintenance

Check mark

Pre-Maintenance Notice

Check mark

Verify that service work is performed by a qualified technician.

Check mark

Ensure only approved Avantco replacement parts are used.

Check mark

Pilot Flame Adjustment

Check mark

Remove pilot adjustment cap.

Check mark

Adjust pilot key to provide properly sized flame as shown in diagram B.

Check mark

Release pilot adjustment cap.

Check mark

Pilot Flame Verification

Check mark

Is the pilot flame surrounding the thermopile for 1/2"?

Run this procedureArrow right

Pressure Regulator Maintenance

Check mark

NOTICE: Warranty and Liability

Check mark

Ensure service work is performed by a qualified technician.

Check mark

Use only approved Avantco replacement parts.

Check mark

WARNING: Qualified Technician Required

Check mark

Confirm adjustments and service work are performed by a qualified technician.

Check mark

Manifold Pressure Check

Check mark

Is the thermostat set to 'OFF' and the gas valve knob to 'PILOT'?

Check mark

Remove pressure tap plug from burner manifold.

Check mark

Install fitting to connect a manometer.

Run this procedureArrow right

1 Daily Floor Fryer Cleaning

Check mark

WARNING: BURN HAZARD

Check mark

If necessary to move the fryer for cleaning, drain oil first to avoid death or serious injury.

Check mark

If disconnection of the restraint is necessary to move the appliance for cleaning, reconnect it when the appliance is moved to its originally installed position.

Check mark

Fryer Cleaning Steps

Check mark

Turn thermostat knob to 'OFF' position.

Check mark

Place hot-oil safe container under the drain and drain the frypot completely.

Check mark

Remove the basket support frame (if applicable) and flush out any sediment remaining in the frypot with a little hot oil.

Check mark

Wipe off the basket support frame and the inside of the frypot with a clean cloth.

Check mark

Close drain valve and strain the oil back into the frypot through several thicknesses of cheesecloth, or filter it back using a filter machine.

Run this procedureArrow right

Parts for Avantco Floor Fryer FF300-N

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Knob, Thermostat

400045

Thermostat Fryer, Regulating 200-400

400044

Combination Valve, Nat

400042

Combination Valve, LP

400146

Tubing, 1/4” Fryer Pilot

400070

Knob, Thermostat

400045

Thermostat Fryer, Regulating 200-400

400044

Combination Valve, Nat

400042

Combination Valve, LP

400146

Tubing, 1/4” Fryer Pilot

400070

Knob, Thermostat

400045

Thermostat Fryer, Regulating 200-400

400044

Combination Valve, Nat

400042

Combination Valve, LP

400146

Tubing, 1/4” Fryer Pilot

400070

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Avantco

Explore Other Assets