ABB Water Drive ACQ580-01-046A-4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Capacitors Check
Warning: This procedure requires trained personnel with PPE!
Capacitors: The intermediate DC circuit of the drive contains several electrolytic capacitors. Operating time, load, and surrounding air temperature have an effect on the life of the capacitors. Capacitor life can be extended by decreasing the surrounding air temperature. Capacitor failure is usually followed by damage to the unit and an input cable fuse failure, or a fault trip. If you think that any capacitors in the drive have failed, contact ABB.
Check capacitor reforming for spare modules and spare capacitors
Reforming the capacitors: The capacitors must be reformed if the drive has not been powered (either in storage or unused) for a year or more. The manufacturing date is on the type designation label.
Enter the manufacturing date of the capacitors
Has the drive been powered in the last year?
Sign off on the capacitor check
1 Yearly Drive Inspection
Check quality of supply voltage
Inspect spare parts
Inspect tightness of terminals
Inspect dustiness, corrosion or temperature
Inspect IP66 (UL Type 4X) frames R1..R3: Drive cover and gasket assembly
1 Yearly Heatsink Cleaning
Electrical safety in installation, start-up and maintenance
Electrical safety precautions
WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur.
If you are not a qualified electrical professional, do not do installation or maintenance work.
Do these steps before you begin any installation or maintenance work.
Clearly identify the work location and equipment.
Disconnect all possible voltage sources. Make sure that re-connection is not possible. Lock out and tag out.
Protect any other energized parts in the work location against contact.
Take special precautions when close to bare conductors.
20 Yearly Functional Safety Components Replacement
Warning: This procedure requires trained personnel with PPE!
Are all components within their mission time?
If any component is beyond its mission time, proceed with the following steps
Choose the type of service done
Post-replacement test passed?
Issues found during the test
Sign off on the safety components replacement
3 Yearly R1- R2 Auxiliary Cooling Fan Replacement
Warning: This procedure requires a qualified electrical professional. Do not attempt if you are not qualified.
Electrical safety precautions
Clearly identified the work location and equipment
Disconnected all possible voltage sources and ensured re-connection is not possible
Protected any other energized parts in the work location against contact
Measured that the installation is de-energized using a quality voltage tester
Installed temporary grounding as required by the local regulations
Obtained a permit to work from the person in control of the electrical installation work
Replacing the auxiliary cooling fan, IP55 (UL Type 12) frames R1...R2
Access the parts list for your equipment in MaintainX.
Circuit Breaker, ABB Type
S 203P-B/C/Z 50
Du/Dt Filter, ABB Drives
NOCH0070-6x
Fuse, ABB Type
OFAF000H63
Fuse, Bussmann Type, DIN 43620 Blade Style
170M1566
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M1316
Circuit Breaker, ABB Type
S 203P-B/C/Z 50
Du/Dt Filter, ABB Drives
NOCH0070-6x
Fuse, ABB Type
OFAF000H63
Fuse, Bussmann Type, DIN 43620 Blade Style
170M1566
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M1316
Circuit Breaker, ABB Type
S 203P-B/C/Z 50
Du/Dt Filter, ABB Drives
NOCH0070-6x
Fuse, ABB Type
OFAF000H63
Fuse, Bussmann Type, DIN 43620 Blade Style
170M1566
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M1316
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.