Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Systema Polska Hot Air Generator BC250RTPA7
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Burner Maximum And Fine Adjustment
Rough Adjustment
Activate the burner and adjust it to maximum thermal load.
Check the gas pressure entering the solenoid valve.
Is the gas pressure not lower than the nominal supply pressure decreased by a maximum of -20%?
Remove the cap of the maximum pressure regulator using a screwdriver.
Adjust the gas and air mixture using the Allen wrench size 3.
Check the gas pressure at the outlet of the solenoid valve.
Does the power comply with the nominal value indicated on the nameplate?
Fine Adjustment
Initial 2 Hours Belt Maintenance
Safety Precautions
Ensure the appliance is disconnected from the power supply
Motor Rotation Check
Remove the V-belts by unlocking the four screws in the motor base
Is the motor rotation direction correct without load?
If incorrect, disconnect power supply and invert the two power supply phases
V-Belt Installation and Alignment
Reinstall the V-belts
Check that the pulleys are aligned
Fuel Replacement
Eolo BC/BL 15÷120 RT
Shut off the gas and electricity supply
Unscrew the cap (A) from the nozzle holder fitting (C)
Unscrew the nozzle (B) located inside the fitting (C)
Choose the nozzle suitable for the type of gas used
Screw the nozzle into the housing (C)
Screw the cap (A) back on
Seal the gas valve adjustment part after calibration
Burner Start and Efficiency Check
1 Yearly Hot Air Generator Maintenance
Pre-Maintenance Safety Precautions
Open the main switch by removing current and close the gas valve.
Place a warning sign on the control panel stating: 'System undergoing maintenance, IT IS FORBIDDEN to perform operations on the control panel of the appliances.'
Ensure all personnel are equipped with safety devices and individual protection.
General Maintenance Checks
Check the general condition of the device.
Check the threaded connections of the gas system and the tightness of the gaskets, replace if necessary.
Check the condition of the electrodes and the combustion head, clean if dirty.
Check the condition of the gas mixer, clean with a rag or brush if necessary.
Burner Parameter Adjustment
Initial Checks
Check ignition at the minimum regulated output of the burner
CO₂ Setting Adjustment
Are there problems with ignition?
Correct the CO₂ setting with the solenoid valve if ignition problems are present
Air/Gas Ratio Adjustment
Does the burner produce resonances at minimum power?
Adjust the air/gas ratio to eliminate resonances
Combustion Analysis
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX