MaintainX Asset Hub logo
EnterprisePricing
Sullair

Sullair Air-Cooled Compressor 10B 30 AC

Need answers fast?
Explore the manual using AI.

Sullair Air-Cooled Compressor 10B 30 AC
Sullair Air-Cooled Compressor 10B 30 AC

The Sullair Air-Cooled Compressor 10B 30 AC is a reliable and efficient industrial compressor designed for various applications. Known for its durability and performance, this model ensures optimal air delivery while minimizing downtime through effective maintenance strategies. Experience enhanced productivity with Sullair's trusted engineering.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Sullair Air-Cooled Compressor 10B 30 AC

Sullair Air-Cooled Compressor 10B 30 AC

Create an account to install this asset package.

Maintenance Plans for Sullair Air-Cooled Compressor Model 10B 30 AC

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Compressor Maintenance

Check mark

Check the fluid level in the sump. Should the level be low, simply add the necessary amount

Check mark

Observe the gauges and indicators to be sure they monitor the correct readings for that particular phase of operation

Check mark

Check on the overall compressor and gauges to assure that the compressor is running properly after it has warmed up

Check mark

Clean the return line strainer after the initial 50 hours of operation

Check mark

Clean the return line orifice after the initial 50 hours of operation

Check mark

Sign off on the daily compressor maintenance

Run this procedureArrow right

1 Yearly Separator Replacement

Check mark

Select the type of compressor

Check mark

Pressure relieved from the sump tank and all compressor lines?

Check mark

All piping connected to the sump cover disconnected?

Check mark

Hex head capscrews from the cover plate loosened and removed?

Check mark

Cover plate lifted from the sump?

Check mark

Separator element removed?

Check mark

Old gasket material scraped from the cover and flange on the sump?

Check mark

New gaskets installed?

Check mark

Separator element reinserted into the sump without denting it?

Run this procedureArrow right

6 Monthly / 1000 Hours Compressor Maintenance

Check mark

Clean the return line strainer

Check mark

Replace the fluid filter element

Check mark

Replace your fluid filter element and the gasket under any of the following conditions, whichever occur first

Check mark

Conditions for replacing fluid filter element

Check mark

To replace fluid filter element:

Check mark

Using a strap wrench, remove the old element and gasket

Check mark

Clean gasket seating surface

Check mark

Apply a light film of fluid to the new gasket

Check mark

Hand tighten new element until new gasket is seated in the gasket groove

Run this procedureArrow right

6 Monthly Air Filter Element Inspection

Check mark

Place a bright light inside the element to inspect for damage or leak holes. Concentrated light will shine through the element and disclose any holes

Check mark

Inspect all gaskets and gasket contact surfaces of the housing. Should faulty gaskets be evident, correct the condition immediately

Check mark

If the clean element is to be stored for later use, it must be stored in a clean container

Check mark

After the element has been installed, inspect and tighten all air inlet connections prior to resuming operation

Check mark

Sign off on the air filter element inspection

Run this procedureArrow right

6 Monthly Air Filter Element Replacement

Check mark

Clean exterior of air filter housing

Check mark

Remove the air filter cover by loosening the wingnut securing the cover

Check mark

Remove element and clean interior of housing using a damp cloth. DO NOT blow dirt out with compressed air

Check mark

Clean or replace the element

Check mark

Replace cover

Check mark

Reset the filter maintenance indicator

Check mark

Sign off on the air filter element replacement

Run this procedureArrow right

Parts for Sullair Air-Cooled Compressor 10B 30 AC

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Air Filter

0410036

Air Inlet Valve

250025–654

Blowdown Valve

250025–655

Check Valve

049905

Element

250025–525

Air Filter

0410036

Air Inlet Valve

250025–654

Blowdown Valve

250025–655

Check Valve

049905

Element

250025–525

Air Filter

0410036

Air Inlet Valve

250025–654

Blowdown Valve

250025–655

Check Valve

049905

Element

250025–525

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Sullair

Explore Other Assets