MaintainX Asset Hub logo
EnterprisePricing
SULLAIR

SULLAIR Water-Cooled Compressor 10B 30HP-251330-003 WC

Need answers fast?
Explore the manual using AI.

SULLAIR Water-Cooled Compressor 10B 30HP-251330-003 WC
SULLAIR Water-Cooled Compressor 10B 30HP-251330-003 WC

The Sullair Water-Cooled Compressor 10B 30HP-251330-003 WC is a robust industrial compressor designed for efficient cooling and air compression. Known for its reliability and performance, this model is ideal for various industrial applications, ensuring optimal operation and longevity.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

SULLAIR Water-Cooled Compressor 10B 30HP-251330-003 WC

SULLAIR Water-Cooled Compressor 10B 30HP-251330-003 WC

Create an account to install this asset package.

Maintenance Plans for SULLAIR Water-Cooled Compressor Model 10B 30HP-251330-003 WC

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Compressor Maintenance

Check mark

Check the fluid level in the sump. Should the level be low, simply add the necessary amount

Check mark

Observe the gauges and indicators to be sure they monitor the correct readings for that particular phase of operation

Check mark

Check on the overall compressor and gauges to assure that the compressor is running properly after it has warmed up

Check mark

Clean the return line strainer after the initial 50 hours of operation

Check mark

Clean the return line orifice after the initial 50 hours of operation

Check mark

Sign off on the daily compressor maintenance

Run this procedureArrow right

1 Yearly Separator Replacement

Check mark

Order separator element repair kit number 250034-112 for 25 and 30HP compressors and repair kit number 250034-114 for 40HP compressors.

Check mark

Relieved all pressure from the sump tank and all compressor lines?

Check mark

Disconnected all piping connected to the sump cover to allow removal (return lines, service lines, etc.)?

Check mark

Loosened and removed the hex head capscrews from the cover plate?

Check mark

Lifted the cover plate from the sump?

Check mark

Removed the separator element?

Check mark

Scraped the old gasket material from the cover and flange on the sump without letting the scraps fall in the sump?

Check mark

Installed the new gaskets; one on the sump tank the other on top of the element?

Check mark

Reinserted the separator element into the sump without denting it against the tank opening?

Run this procedureArrow right

6 Monthly / 1000 Hours Compressor Maintenance

Check mark

Clean the return line strainer

Check mark

Replace the fluid filter element

Check mark

Replace your fluid filter element and the gasket under any of the following conditions, whichever occur first

Check mark

Conditions for replacing fluid filter element

Check mark

To replace fluid filter element:

Check mark

Using a strap wrench, remove the old element and gasket

Check mark

Clean gasket seating surface

Check mark

Apply a light film of fluid to the new gasket

Check mark

Hand tighten new element until new gasket is seated in the gasket groove

Run this procedureArrow right

6 Monthly Air Filter Element Inspection

Check mark

Warning: This inspection requires trained personnel with PPE!

Check mark

Bright light test for damage or leak holes

Check mark

Gaskets and gasket contact surfaces inspection

Check mark

Faulty gaskets found?

Check mark

If faulty gaskets are found, correct the condition immediately

Check mark

Clean element stored in a clean container?

Check mark

All air inlet connections inspected and tightened

Check mark

Sign off on the air filter element inspection

Run this procedureArrow right

6 Monthly Air Filter Element Replacement

Check mark

Clean exterior of air filter housing

Check mark

Remove the air filter cover by loosening the wingnut securing the cover

Check mark

Remove element and clean interior of housing using a damp cloth. DO NOT blow dirt out with compressed air

Check mark

Clean or replace the element

Check mark

Replace cover

Check mark

Reset the filter maintenance indicator

Check mark

Sign off on the air filter element replacement

Run this procedureArrow right

Parts for SULLAIR Water-Cooled Compressor 10B 30HP-251330-003 WC

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Air Filter

0410036

Air Inlet Valve

250025–654

Blowdown Valve

250025–655

Check Valve

049905

Element

250025–525

Air Filter

0410036

Air Inlet Valve

250025–654

Blowdown Valve

250025–655

Check Valve

049905

Element

250025–525

Air Filter

0410036

Air Inlet Valve

250025–654

Blowdown Valve

250025–655

Check Valve

049905

Element

250025–525

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from SULLAIR

Explore Other Assets