The Parker Hannifin NitroFlow60NA is a high-performance nitrogen generator designed for industrial applications. This reliable asset efficiently produces nitrogen on-site, ensuring optimal purity levels and reducing operational costs. Ideal for various industries, the NitroFlow60NA enhances productivity and reliability in nitrogen supply.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Parker Hannifin Nitrogen Generator NitroFlow60NA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
8700 Hours Bearings Greasing
Grease Orbital Scroll Compressor Bearings
Remove the plastic dust cap from the pump
Rotate the compressor pulley until the grease fitting is visible in the dust cap hole
Using a grease gun extension adapter to engage the grease fitting, supply the proper amount of grease
NOTE! Pump grease gun before feeding to eliminate air from the needle adapter. Each pump equals 0.65 grams of grease. The volume of grease is less after the 2nd pump since some grease remains in the extension adapter.
Replace the plastic dust cap
Grease Pin Crank Bearing
Remove the side service panel
Remove the fan duct
8700 Hours Belts Maintenance
Remove the top panel on the unit by removing two screws at the rear with a phillips head screwdriver and pulling top panel to the rear.
Remove the generator cabinet on the unit by removing two screws with a phillips head screwdriver.
Loosen (do not remove) three hex head screws located at the front of the cabinet.
Remove compressed air inlet tube from generator cabinet.
Pull cabinet to the rear and lift off of compressor cabinet. Be cautious of exterior pre-filters.
Check belt tension using a belt tension gauge or the deflection method. Tension gauge should indicate minimum 45 lbs. If using the deflection method, 3.0-3.38 lbs force at mid span should yield 7/32” belt deflection.
When making adjustments to the belts, make sure that pulley misalignment is no more than 1/16” and that both pulleys are not misaligned by more than 1/16” also.
Adjust tension if required by adjusting motor bracket. Replace belts if needed.
Sign off on the belt maintenance
8700 Hours Carbon Modules Replacement
Warning: Generator must be set to “OFF” and pressure gage must read zero before filter replacement.
Top panel removed from the NitroFlow60 Generator Series
Plastic tubing disconnected from the press fittings on the inlet and outlet ports of the module
Hook and loop strap released and module slid out of the bracket
New carbon module replaced with correct orientation
New module slid into the bracket fully and hook and loop strap re-attached
Inlet and outlet tubing re-inserted
No leaks detected when pressurizing the unit
Sign off on the carbon modules replacement
8700 Hours Coalescing Filters Replacement
Warning: Ensure to install the proper grade filter into the proper housing.
Enter the type of replacement element used
Twisted the bowl loose from the head of the assembly, counter clockwise, without damaging the o-ring?
Unscrewed the element retainer at the base of the element and replaced the spent element with a new one?
Reassembled by reversing the steps and ensured the o-ring is sealed in the groove before reinstalling the bowl?
Sign off on the filter replacement
8700 Hours Nitrogen Filter Replacement
Warning: Ensure the machine is powered off before starting the procedure.
Upper side panel removed
First intake filter cap removed
Second intake filter cap removed
Upload a photo of the old filter elements
New filter elements installed
Reassembled correctly
Sign off on the filter replacement
Access the parts list for your equipment in MaintainX.
Bottle Drain Kit
B04-0540
Carbon Module
B04-0525
Exhaust Ventilation Kit
B04-0575
Filter Element
B2104N-0B1-BX
Filter Element
100-18-DX
Bottle Drain Kit
B04-0540
Carbon Module
B04-0525
Exhaust Ventilation Kit
B04-0575
Filter Element
B2104N-0B1-BX
Filter Element
100-18-DX
Bottle Drain Kit
B04-0540
Carbon Module
B04-0525
Exhaust Ventilation Kit
B04-0575
Filter Element
B2104N-0B1-BX
Filter Element
100-18-DX
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX