The Parker Hannifin Adsorption Dryer KMT6 is a high-performance industrial dryer designed to remove moisture from compressed air systems. This reliable equipment ensures optimal operation and longevity of pneumatic tools and machinery, making it essential for various industrial applications.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Parker Hannifin Adsorption Dryer KMT6
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
12 Months Dewpoint Sensor Replacement
Warning: The dew point sensor is a sensitive measuring device. Handle with care.
Did you contact the manufacturer and order a new dewpoint sensor?
Upload a photo of the new dewpoint sensor
Did you release pressure from dryer and shut down the unit?
Did you loosen the screw at the adapter and disconnect signal cable with the adapter and seal?
Did you remove the old dewpoint sensor from the sensor cell by turning the nut?
Upload a photo of the removed old dewpoint sensor
Did you take the new dewpoint sensor from the box, remove the protective caps and screw it into the sensor chamber?
Did you place seal onto sealing face; connect adapter and secure it by tightening the screw?
12 Months Fine Filter Muffler Replacement
Depressurise the dryer and shut it down
Undo knurled screw on the lid cap and remove cap
Unscrew old filter element. Arrows on the element bottom mark the direction of rotation
Insert new filter element and screw on tightly
Re-engage lid cap at the top section of the housing and fix in position by means of the knurled screw
Restart dryer
Sign off on the filter muffler replacement
12 Months Muffler Replacement
Warning: Hazard caused by blocked muffler! Blocked mufflers can cause a dangerous overpressure to build up which may cause the mufflers to burst. Flying fragments may cause personal injury and damage to property.
Warning against sudden air ejection! During expansion the pressure is released suddenly through the muffler: A loud cracking noise occurs which can injure your hearing. Particles carried in the air flow act like bullets and can injure your eyes or skin. Always wear eye and ear protection, therefore, when you are in the vicinity of the dryer!
Muffler checked and cleaned or renewed if contaminated?
Dryer depressurised and shut down?
Muffler unscrewed?
Muffler replaced annually and after each desiccant change?
Sound absorber screwed tight again?
Dryer restarted?
Sign off on the muffler replacement
1 Daily Dryer Maintenance
Visual check for external damage on the dryer
Functional check for unusual noise generation from the dryer
Describe any defects found
Is the message 'SEr.' displayed on the dryer?
If 'SEr.' message is displayed, contact the service department of the manufacturer.
Dryer cleaned of loose dust
Dryer surfaces cleaned with a moist well wrung cloth
Sign off on the daily dryer maintenance
24 Months Membranes of Solenoid Valve Replacement
Warning: This procedure requires trained personnel with PPE!
Pressure released from dryer and unit shut down?
Specifications of the valves checked?
Solenoid valves Y1/Y2 at the dryer rear open when not energised?
Solenoid valves Y3/Y4 at the dryer front closed when not energised?
New solenoid valves positioned at the points at which they are to be mounted?
Solenoid valve removed from the holder?
New diaphragm inserted and secured to the holder?
New solenoid positioned onto the armature and secured to the spring bracket?
Access the parts list for your equipment in MaintainX.
Desiccant pack
DESPAC1MS
Desiccant pack
DESPAC4MS
Downstream Filter
GL5ZLDH
Service Kit
SKK6-K7/D2/48/115
Service Kit
SKK6-K7/D2/24
Desiccant pack
DESPAC1MS
Desiccant pack
DESPAC4MS
Downstream Filter
GL5ZLDH
Service Kit
SKK6-K7/D2/48/115
Service Kit
SKK6-K7/D2/24
Desiccant pack
DESPAC1MS
Desiccant pack
DESPAC4MS
Downstream Filter
GL5ZLDH
Service Kit
SKK6-K7/D2/48/115
Service Kit
SKK6-K7/D2/24
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX