MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Split-Type Air Conditioner PUZ-A30NHA7-BS

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type Air Conditioner PUZ-A30NHA7-BS
Mitsubishi Split-Type Air Conditioner PUZ-A30NHA7-BS

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type Air Conditioner PUZ-A30NHA7-BS

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type Air Conditioner PUZ-A30NHA7-BS

Mitsubishi Split-Type Air Conditioner PUZ-A30NHA7-BS

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type Air Conditioner Model PUZ-A30NHA7-BS

Integrate maintenance plans directly into your work orders in MaintainX.

Outdoor Unit 4-Way Valve Coil And LEV Coils Replacement

Check mark

(1) Remove the service panel. (See Photo 1)

Check mark

(2) Remove the top panel. (See Photo 1)

Check mark

(3) Remove the electrical parts box. (See Photo 4)

Check mark

[Removing the 4-way valve coil]

Check mark

(4) Remove 4-way valve coil fixing screw (M4 × 6).

Check mark

(5) Remove the 4-way valve coil by sliding the coil toward you.

Check mark

(6) Disconnect the connector 21S4 (green) on the controller board in the electrical parts box.

Check mark

[Removing the LEV coil]

Check mark

(4) Remove the LEV coil by sliding the coil upward.

Run this procedureArrow right

Outdoor Unit 4-Way Valve Replacement

Check mark

Upload Photo 1 of the service panel and top panel removed

Check mark

Upload Photo 4 of the electrical parts box removed

Check mark

Valve bed removed successfully?

Check mark

Upload Photo of the right side panel removed

Check mark

Upload Photo 9 of the 4-way valve coil removed

Check mark

Refrigerant recovered successfully?

Check mark

Welded part of 4-way valve removed successfully?

Check mark

Note 1: Recover refrigerant without spreading it in the air.

Check mark

Note 2: The welded part can be removed easily by removing the right side panel.

Run this procedureArrow right

Outdoor Unit Compressor Replacement

Check mark

Upload Photo 1 of the service panel removal

Check mark

Upload Photo 1 of the top panel removal

Check mark

Upload Photo 1 of the front cover panel removal

Check mark

Back cover panel removed?

Check mark

Upload Photo 4 of the electrical parts box removal

Check mark

Valve bed removed?

Check mark

Right side panel removed?

Check mark

Separator removed?

Check mark

Amount of refrigerant recovered

Run this procedureArrow right

Outdoor Unit Electrical Parts Box Replacement

Check mark

Upload a photo of the service panel before removal

Check mark

Service panel removed successfully

Check mark

Upload a photo of the top panel before removal

Check mark

Top panel removed successfully

Check mark

Indoor/outdoor connecting wire disconnected from terminal block

Check mark

Connector CNF1, LEV-A and LEV-B disconnected from the controller circuit board

Check mark

Disconnect the pipe-side connections of the following parts

Check mark

Terminal cover removed and compressor lead wire disconnected

Check mark

Electrical parts box fixing screw removed and electrical parts box detached

Run this procedureArrow right

Outdoor Unit Fan Motor Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove 5 fan grille fixing screws (5 × 12) to detach the fan grille

Check mark

Upload a photo of the detached fan grille

Check mark

Remove a nut (for right handed screw of M6) to detach the propeller

Check mark

Upload a photo of the detached propeller

Check mark

Disconnect the connector CNF1 on controller circuit board in electrical parts box

Run this procedureArrow right

Parts for Mitsubishi Split-Type Air Conditioner PUZ-A30NHA7-BS

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Starter Type, Hermetic Compressor - 1,2 KW

SNB172FWHM1

Inverter Starter Type, Hermetic Compressor - 1,2 KW

SNB172FWHM1

Inverter Starter Type, Hermetic Compressor - 1,2 KW

SNB172FWHM1

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets