Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mitsubishi Split-Type Air Conditioner PUY-A30NHA6-BS
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
TH7 Thermistor Replacement
Upload a photo of the service panel before removal
Service panel removed
Upload a photo of the top panel before removal
Top panel removed
TH7 connector disconnected
Lead wire clamp loosened
Thermistor <Ambient> (TH7) pulled out
Note: In case of replacing thermistor <Ambient> (TH7), replace it together with thermistor <2-phase pipe> (TH6), since they are combined together.
Thermistor <2-phase pipe> (TH6) removed
Reactor A24 Replacement
Service panel removed
Upload a photo of the removed service panel
Top panel removed
Upload a photo of the removed top panel
Electrical parts box removed
Upload a photo of the removed electrical parts box
Reactor fixing screws removed
Upload a photo of the removed reactor
Sign off on the reactor replacement
Outdoor Unit Refrigirant Charging
Cautions for service
Refrigerant recovered from the unit completely
Refrigerant not released in the air
Cycle charged with specified amount of refrigerant
Filter drier installed
Additional refrigerant charge
Cylinder for R410A is a syphon type
Charging performed with the cylinder of syphon stood vertically
Service tools
4-Way Valve Coil,Linear Expansion Valve Coil And Bypass Valve Coil Replacement
(1) Remove the service panel. (See Figure 1)
(2) Remove the top panel. (See Figure 1)
(3) Remove the electrical parts box. (See Photo 3)
[Removing the 4-way valve coil]
(4) Remove 4-way valve coil fixing screw (M4 × 6).
(5) Remove the 4-way valve coil by sliding the coil toward you.
(6) Disconnect the connector 21S4 (green) on the controller board in the electrical parts box.
[Removing the linear expansion valve coil]
(4) Remove the linear expansion valve coil by sliding the coil upward.
TH3 Thermistor Replacement
Service panel removed
Connector TH3 (white) on the controller circuit board in the electrical parts box disconnected
Clamp for the lead wire in the rear of the electrical parts box loosened
Thermistor <Liquid> (TH3) pulled out from the sensor holder
Sign off on the thermistor replacement
Access the parts list for your equipment in MaintainX.
Inverter Starter Type, Hermetic Compressor - 1,3 KW
TNB220FLHM
Inverter Starter Type, Hermetic Compressor - 1,3 KW
TNB220FLHM
Inverter Starter Type, Hermetic Compressor - 1,3 KW
TNB220FLHM
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX