Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Midmark Steam Sterilizer M11-022
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Weekly Maintenance
Equipment Alert: Failure to change water may result in sterilizer malfunction. Do not use bleaching agents or any abrasive materials / substances in chamber (i.e. bleach, steel wool, wire brush, scouring powder, etc.). Failure to comply may result in damage to the chamber and/or other components.
Note: Every seven days, the autoclave will automatically display the PERFORM WEEKLY MAINTENANCE message. If power is disconnected, the cycle of weekly messages will be reset.
Clean Chamber / Trays (including Rack and Plate):
Caution: To prevent burns, allow unit to cool before draining reservoir.
Disconnect the upper portion of the reservoir drain tube from the panel clips, bend it downward, and drain the reservoir water into a suitable container, e.g. a bucket, and dispose of the water.
Remove the trays, tray rack, and tray plate from the sterilizer.
Wash trays, rack, plate, and inside of chamber with mild soap or Speed-Clean and distilled water or water that meets the referenced water purity specifications.
Refill reservoir with distilled water or water that meets the referenced water purity specifications.
Warning: Allow unit to cool before removing or installing tray rack and plate. Handle metal tray rack carefully to avoid injury. Do not run sterilizer without tray plate in place.
1 Daily Maintenance
Equipment Alert: If the sterilizer is used frequently to process dental handpieces that have been lubricated or dipped in dental milks, drain the water from the reservoir daily. Refill the reservoir with distilled water or water that meets the referenced water purity specifications.
Drained the water from the reservoir
Refilled the reservoir with distilled water or water that meets the referenced water purity specifications
Clean External Surfaces:
Washed the exterior of the sterilizer according to your facility’s procedure for clinical contact surfaces
Used only quaternary disinfectants to disinfect unit
Wring excess solution from the cloth
Using soft cloth, wiped all external surfaces
Followed the instructions provided with the cleaner / disinfectant used regarding rinsing and drying of the external surfaces
1 Monthly Maintenance
Warning: Do not process instruments while flushing system.
Equipment Alert: Use only Speed-Clean to flush system. Failure to flush system with Speed-Clean may result in the premature failure of sterilizer components.
Note: Every 28 days, the sterilizer will automatically display the PERFORM MONTHLY MAINTENANCE message. If power is disconnected, the cycle of monthly messages will be reset.
Clean Chamber / Plumbing:
Caution: To prevent burns, allow unit to cool before draining reservoir.
With a cooled chamber, drain the sterilizer’s reservoir and refill with clean distilled water or water that meets the referenced water purity specifications. Add one ounce of Speed-Clean sterilizer cleaner directly to the bottom of chamber.
Run one Pouches cycle.
Press Stop button when Dry Cycle begins. (Dry Cycle is not needed during maintenance.)
Drain reservoir and refill a second time with clean distilled water or water that meets the referenced water purity specifications.
Access the parts list for your equipment in MaintainX.
Speed-Clean
002-0396-00
Speed-Clean
002-0396-05
Printer
9A259001
Printer Refill Kit
002-0371-00
Casette Rack
9A215001
Speed-Clean
002-0396-00
Speed-Clean
002-0396-05
Printer
9A259001
Printer Refill Kit
002-0371-00
Casette Rack
9A215001
Speed-Clean
002-0396-00
Speed-Clean
002-0396-05
Printer
9A259001
Printer Refill Kit
002-0371-00
Casette Rack
9A215001
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX