MaintainX Logo
EnterprisePricing
Midmark

Midmark Steam Sterilizer M11-021

Need answers fast?
Explore the manual using AI.

Midmark Steam Sterilizer M11-021
Midmark Steam Sterilizer M11-021

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Midmark Steam Sterilizer M11-021

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Midmark Steam Sterilizer M11-021

Midmark Steam Sterilizer M11-021

Create an account to install this asset package.

Maintenance Plans for Midmark Steam Sterilizer Model M11-021

Integrate maintenance plans directly into your work orders in MaintainX.

1 Weekly Maintenance

Check mark

Equipment Alert: Failure to change water may result in sterilizer malfunction. Do not use bleaching agents or any abrasive materials / substances in chamber (i.e. bleach, steel wool, wire brush, scouring powder, etc.). Failure to comply may result in damage to the chamber and/or other components.

Check mark

Note: Every seven days, the autoclave will automatically display the PERFORM WEEKLY MAINTENANCE message. If power is disconnected, the cycle of weekly messages will be reset.

Check mark

Clean Chamber / Trays (including Rack and Plate):

Check mark

Caution: To prevent burns, allow unit to cool before draining reservoir.

Check mark

Disconnect the upper portion of the reservoir drain tube from the panel clips, bend it downward, and drain the reservoir water into a suitable container, e.g. a bucket, and dispose of the water.

Check mark

Remove the trays, tray rack, and tray plate from the sterilizer.

Check mark

Wash trays, rack, plate, and inside of chamber with mild soap or Speed-Clean and distilled water or water that meets the referenced water purity specifications.

Check mark

Refill reservoir with distilled water or water that meets the referenced water purity specifications.

Check mark

Warning: Allow unit to cool before removing or installing tray rack and plate. Handle metal tray rack carefully to avoid injury. Do not run sterilizer without tray plate in place.

Run this procedureArrow right

1 Monthly Maintenance

Check mark

Warning: Do not process instruments while flushing system.

Check mark

Equipment Alert: Use only Speed-Clean to flush system. Failure to flush system with Speed-Clean may result in the premature failure of sterilizer components.

Check mark

Note: Every 28 days, the sterilizer will automatically display the PERFORM MONTHLY MAINTENANCE message. If power is disconnected, the cycle of monthly messages will be reset.

Check mark

Clean Chamber / Plumbing:

Check mark

Caution: To prevent burns, allow unit to cool before draining reservoir.

Check mark

With a cooled chamber, drain the sterilizer’s reservoir and refill with clean distilled water or water that meets the referenced water purity specifications. Add one ounce of Speed-Clean sterilizer cleaner directly to the bottom of chamber.

Check mark

Run one Pouches cycle.

Check mark

Press Stop button when Dry Cycle begins. (Dry Cycle is not needed during maintenance.)

Check mark

Drain reservoir and refill a second time with clean distilled water or water that meets the referenced water purity specifications.

Run this procedureArrow right

1 Daily Maintenance

Check mark

Equipment Alert: If the sterilizer is used frequently to process dental handpieces that have been lubricated or dipped in dental milks, drain the water from the reservoir daily. Refill the reservoir with distilled water or water that meets the referenced water purity specifications.

Check mark

Clean External Surfaces: Wash the exterior of the sterilizer each day according to your facility’s procedure for clinical contact surfaces

Check mark

Wring excess solution from the cloth.

Check mark

Using soft cloth, wipe all external surfaces.

Check mark

Follow the instructions provided with the cleaner / disinfectant used regarding rinsing and drying of the external surfaces.

Check mark

Caution: To prevent burns, allow unit to cool before cleaning gaskets and mating surfaces.

Check mark

Examine gaskets for possible damage.

Check mark

Clean gaskets and mating surfaces with a damp cloth.

Check mark

Sign off on the daily maintenance

Run this procedureArrow right

Parts for Midmark Steam Sterilizer M11-021

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Speed-Clean

002-0396-00

Speed-Clean

002-0396-05

Printer

9A259001

Printer Refill Kit

002-0371-00

Casette Rack

9A215001

Speed-Clean

002-0396-00

Speed-Clean

002-0396-05

Printer

9A259001

Printer Refill Kit

002-0371-00

Casette Rack

9A215001

Speed-Clean

002-0396-00

Speed-Clean

002-0396-05

Printer

9A259001

Printer Refill Kit

002-0371-00

Casette Rack

9A215001

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Midmark

Explore Other Assets