Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mercer Valve Pressure Relief Valve 81-11151P18G11
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Gauge Calibration
Warning: This procedure requires trained personnel!
Are two pressure gauges used for testing?
Are the gauges reading identical values within their respective tolerances?
Select the type of the first gauge
Select the type of the second gauge
Is the analog (dial) gauge not liquid filled?
Does the digital gauge respond to quick pressure increases?
Does the test gauge have at least 0.25% accuracy over their full scale?
Is the portion of the gauge used more stringent than the set pressure's tolerance?
1 Yearly Pressure Relief Valve Leak Inspection
Warning: This inspection requires trained personnel with PPE!
Set pressure of the valve verified?
Enter the leak test pressure
Contact Mercer Valve Co. Inc. for proper leak pressure and specification for the valve.
Pressure held steady during the test?
Any leakage observed during the test?
Choose the method used for testing leakage
If the valve cannot be leak checked by normal means, maintain a blocked in pressure in the valve's inlet.
Pressure remained stable during the test?
1 Yearly Pressure Relief Valve Maintenance
For dependable performance, PRVs must be maintained regularly.
Mercer Valve Co., Inc. recommends its PRVs are inspected and tested annually.; After the valve has been in installed and a service history has been established, the testing and inspection frequency may be adjusted.
Some guidelines for testing frequencies are found in NB-23, API 576, and API 598.; Additionally, government jurisdiction should be reviewed.; When maintenance is done, qualified repair personnel should perform it.; Qualified repair personnel conducting the annual inspection and testing may alter the maintenance schedule based on the service conditions.
During the inspection, a visual inspection, a set pressure verification, and a leak check should be completed.; These tests can be performed while the PRV is installed on its system or when it’s on a testing bench.; The PRV can only be tested while on its application if there is a method and procedure to apply a controlled pressure to the PRV’s inlet without exceeding any limits of the system.
A visual inspection is used to identify if the PRV is installed properly, is correct for the application, and doesn’t have apparent problems.
Check the nameplate information to verify that the valve is installed on the proper service. A missing nameplate requires immediate addressing.
If the valve is installed on gas/vapor service, the nameplate’s capacity will indicate an air capacity at standard conditions.
If the valve is on liquid service, the nameplate will indicate a water capacity.
Check the seal wire. A broken seal wire indicates that an unqualified person has adjusted the set pressure this also removes any warranty the valve had.
1 Yearly Pressure Relief Valve Set Pressure Inspection
During the set pressure inspection, the set pressure is verified in accordance with the ASME BPVC.
For all valves set 70psi (500kPa) and above, the set pressure has a tolerance of $3% of the set pressure.
For all set pressure below 70psi (500kPa) the tolerance is (±2psi ((±15kPa).
If the valve has a CDTP associated with it due to temperature and/or backpressure, the test pressure is checked to the CDTP.; Even with a CDTP the set pressure tolerance is calculated based on the actual nameplate set pressure.; The set pressure test should be performed before and after any repairs.
The set pressure is inspected to the definition listed in NB-18, a publication by the National Board of Pressure Vessel Inspectors, which is found at http://www.nationalboard.org/.
This publication lists all ASME BPVC certified pressure relief valves.
It indicates the correct set pressure definition and other characteristics of a valve.; The set pressure has been defined to achieve a particular operational characteristics.; If the wrong set pressure definition is used in the inspection test, the valve's set pressure will not be accurate and it may not operate appropriately.
The correct fluid for testing has to be used to achieve accurate results.; For gas/vapor service, nitrogen or compressed air is used as the test fluid, while for liquid service, water is used.; If the incorrect fluid is used during the testing, the test's results will be inaccurate.; Depending on the size of the valve and its set pressure, the set pressure discrepancy can vary outside of ASME tolerances.
Setting procedures should be in accordance with ASME PTC 25.; The rate of the system pressure increase should be slow when the pressure is within 15% of the set pressure. Within this range, the rate should never be more than 2psi/sec (15kPa/sec).; Ideally each pressure increment on the pressure gauge should be clearly read as the pressure is increased. Slow pressure increase helps to accurately read the pressure gauge.
1 Yearly Pressure Relief Valve Visual Inspection
Warning: Ensure the valve is not pressurized before starting the inspection
Cap and Seal Wire in good condition
Security seal on the seal wire intact
Flanges Connections in good condition
Threaded Connection in good condition
Outlet free from corrosion or debris
External Surface free from damage
Valve Tag information corresponds to the service conditions
If any of the checks fail, do not proceed with the set pressure inspection and the leak inspection
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX