M&J Valve Gate Valve M-303A
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Gate Valve (Integral T-bar, with bolted stem packing retainer, and with cupola) Stem Replacement
Preliminary Steps
Ensure replacement stem is available
Ensure replacement stem packing and O-rings are available
Include valve serial number in correspondence with M&J Valve
Safety Precautions
Ensure valve is not exposed to line pressure during maintenance
Isolation and Venting
Isolate pressure source from the pipeline and valve
Cycle the valve to the mid travel position
Gate Valve (Screw on T-bar, with bolted stem packing retainer, and without cupola) Stem Replacement
Preparation and Safety
Ensure replacement stem is available
Ensure stem packing and O-rings are available for replacement
Verify valve serial number for correspondence with M&J Valve
Ensure no line pressure is present before starting maintenance
Isolation and Venting
Isolate pressure source from the pipeline and valve
Cycle the valve to the mid travel position
Open body pressure relief valve to vent trapped body/line pressure
Gate Valve (Integral T-bar, with bolted stem packing retainer, and without cupola) Stem Replacement
Preparation and Safety
Ensure replacement stem is available
Ensure stem packing and O-rings are available
Include valve serial number in correspondence with M&J Valve
Isolate pressure source from the pipeline and valve
Valve Positioning and Pressure Venting
Cycle the valve to the mid travel position
Open body pressure relief valve to vent trapped body/line pressure
Cycle the valve to the full open position after venting is complete
Gate Valve Handwheel Lubrication
Preparation
Cycle the gate to the full open position.
Remove the stem protector, including cap and sealing device.
Remove the indicator rod.
If there is a downstop bolt on top of the valve stem, remove the indicator rod and downstop bolt.
Inspection and Lubrication
Inspect valve stem threads for damage and lubrication.
Apply a coat of light oil or a lubricant such as WD-40 to the stem threads and top of operator drive nut.
Handwheel Operator Removal
Gate Valve (Integral T-bar, with or without slip-on stem packing retainer bushing, and without cupola) Stem Replacement
Preliminary Steps
Ensure replacement stem is available
Ensure replacement stem packing and o-rings are available
Include valve serial number in correspondence with M&J Valve
Safety Precautions
Ensure valve is not exposed to line pressure during maintenance
Valve Isolation and Venting
Isolate pressure source from pipeline and valve
Cycle the valve to the mid travel position
Access the parts list for your equipment in MaintainX.
Pry Bar
154406
Lifting Rod, 2-12"
261610
Lifting Rod, 14-20"
60389
Lifting Rod, 22-30"
60391
Lifting Rod, 32-42"
60390
Pry Bar
154406
Lifting Rod, 2-12"
261610
Lifting Rod, 14-20"
60389
Lifting Rod, 22-30"
60391
Lifting Rod, 32-42"
60390
Pry Bar
154406
Lifting Rod, 2-12"
261610
Lifting Rod, 14-20"
60389
Lifting Rod, 22-30"
60391
Lifting Rod, 32-42"
60390
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.