Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Komatsu Hydraulic Excavator PC450LC-6
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly Corrosion Resistor Cartridge Replacement
Warning: This procedure requires trained personnel with PPE!
Screw in valve ① at the top of the corrosion resistor
Using a filter wrench, turn cartridge ② to the left to remove it
Coat the seal surface of the new filter cartridge with engine oil, then install it
When installing, bring the packing surface into contact with the seal surface of the filter holder, then tighten a further 2/3 turn
Always use a genuine Komatsu cartridge
Open valve ①
Run the engine and check that there is no leakage of water from the seal surface
Sign off on the cartridge replacement
1000 Hourly Damper Case Oil Level Check
WARNING: The oil is at high temperature immediately after the machine has been operated. Wait for the oil to cool down before carrying out maintenance
NOTICE: Park the machine on flat ground and stop the engine. After waiting for more than 30 minutes after stopping the engine, check the oil level
Machine parked on flat ground and engine stopped?
Waited for more than 30 minutes after stopping the engine?
Door on the left side of the machine opened?
Plug Ⓖ removed and oil level checked?
If insufficient, was plug Ⓕ removed and oil added through the hole of plug Ⓕ up to the bottom of the plug hole Ⓖ?
NOTICE: For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”
If excess oil is supplied, was it drained to the specified amount to avoid overheating?
1000 Hourly Hydraulic Excavator Maintenance
Check all tightening parts of turbocharger
Report any issues found during the check
Check play of turbocharger rotor
Report any issues found during the check
Sign off on the hydraulic excavator maintenance
1000 Hourly Swing Machinery Oil Change
WARNING: The oil is at high temperature immediately after the machine has been operated. Wait for the oil to cool down before carrying out maintenance.
Container to catch drained oil: Min. 21.5 ℓ capacity
Refill capacity: 21.5 ℓ (5.7 US gal, 4.7 UK gal)
Set a container under drain valve Ⓔ under the machine body to catch the oil
Loosen drain valve Ⓔ under the machine body, drain the oil, then tighten the drain plug again
Remove dipstick Ⓖ and air bleed plug ①, then add the specified amount of engine oil through filler port Ⓕ of the dipstick guide
NOTICE: For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”
After adding oil, install air bleed plug ①
Wipe off the oil on the dipstick with a cloth
100 Hourly Fuel Tank Maintenance
Carry out this procedure before operating the machine
Prepare a container to catch the fuel that is drained
Open valve ① at the bottom of the tank and drain the sediment and water that has accumulated at the bottom together with fuel
When doing this, be careful not to get fuel on yourself
When only clean fuel comes out, close drain valve ①
NOTICE: Never use trichlene for washing the inside of the tank
Sign off on the fuel tank maintenance
Access the parts list for your equipment in MaintainX.
Bolt, Shroud Type Shroud Bucket
01011-83005
Bolt, Side Cutter Type Bucket
198-32-14210
Cartridge, Corrosion Resistor
600-411-1151
Cartridge, Engine Bypass Filter
600-212-1511
Cartridge, Engine Oil Filter
6136-51-1231
Bolt, Shroud Type Shroud Bucket
01011-83005
Bolt, Side Cutter Type Bucket
198-32-14210
Cartridge, Corrosion Resistor
600-411-1151
Cartridge, Engine Bypass Filter
600-212-1511
Cartridge, Engine Oil Filter
6136-51-1231
Bolt, Shroud Type Shroud Bucket
01011-83005
Bolt, Side Cutter Type Bucket
198-32-14210
Cartridge, Corrosion Resistor
600-411-1151
Cartridge, Engine Bypass Filter
600-212-1511
Cartridge, Engine Oil Filter
6136-51-1231
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX