Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

JLG Driveable Stock Picker 15MSP
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Driveable Stock Picker Pre-Start Inspection
Mast Assembly: Clean and free of debris
Platform Assembly: Clean and free of debris
Chassis Assembly: Clean and free of debris
Caster Wheels: Check for proper and secure installation. Visual inspection for damage, cracks, distortion, or excessive wear
Functions / Controls: Clean and free of debris
Power System: If Fully charged
Hydraulic / Electric System: Check for signs of leakage
Hydraulic Fluid: Check for proper fluid level. Drain and refill with fresh hydraulic fluid every two years
Instruments, Gauges, Switches, Lights, Horn: If Operates properly
1 Yearly Driveable Stock Picker Maintenance
Mast Assembly:
- Mast Sections: Visual inspection for damage, cracks, distortion, or excessive wear. Operates properly.
- Chain Systems: Properly lubricated. Inspected per Service and Maintenance Manual.
- Sequence Cable Systems: Check for proper and secure installation. Visual inspection for damage, cracks, distortion, or excessive wear. Check for proper adjustment.
- Covers or Shields: Check for proper and secure installation.
- Sheave Systems: Check for proper and secure installation. Visual inspection for damage, cracks, distortion, or excessive wear.
- Bearings: Check for proper and secure installation. Visual inspection for damage, cracks, distortion, or excessive wear.
- Slide Pads: Check for proper and secure installation. Visual inspection for damage, cracks, distortion, or excessive wear.
Platform Assembly:
1 Yearly Hydraulic Oil Change
Warning: Use only recommended hydraulic oils to avoid the need for regular oil changes.
Avoid mixing petroleum and synthetic base oils.
JLG Industries recommends changing the hydraulic oil annually.
Is the hydraulic oil clean?
If the oil must be poured from the original container into another, be sure to clean all possible contaminants from the service container.
Is the service container clean?
While the unit is shut down, a good preventive maintenance measure is to make a thorough inspection of all hydraulic components, lines, fittings, etc., as well as a functional check of each system, before placing the machine back in service.
Check all that apply
Sign off on the hydraulic oil change
Battery Replacement
Notice: JLG MACHINES EQUIPPED WITH DELTA-Q BATTERY CHARGERS ARE DESIGNED FOR THE BEST PERFORMANCE WITH OEM FACTORY APPROVED BATTERIES.
APPROVED JLG REPLACEMENT BATTERIES ARE AVAILABLE THROUGH JLG’S AFTERMARKET PARTS DISTRIBUTION CENTERS OR JLG’S AFTERMARKET PROGRAMS.
FOR ASSISTANCE WITH PROPER BATTERY REPLACEMENT, PLEASE CONTACT YOUR LOCAL JLG SUPPORT OFFICE.
BATTERIES APPROVED BY JLG HAVE BEEN TESTED FOR COMPATIBILITY WITH THE ALGORITHM PROGRAMMING OF THE DELTA Q BATTERY CHARGER TO OPTIMIZE BATTERY LIFE AND MACHINE CYCLE TIMES.
THE USE OF NON APPROVED BATTERIES IN YOUR JLG EQUIPMENT MAY RESULT IN PERFORMANCE ISSUES OR BATTERY CHARGER FAULT CODES. JLG ASSUMES NO RESPONSIBILITY FOR SERVICE OR PERFORMANCE ISSUES ARISING FROM THE USE OF NON APPROVED BATTERIES.
Replacement battery(s) must be of equivalent voltage and amperage output as the OEM battery(s) in order for the machine to operate to as manufactured specifications.
Battery replacement part weight must also be equivalent to OEM per battery, in order to maintain machine stability as manufactured. (See Section-1 of this manual for battery specifications).
Warning: DO NOT REPLACE ITEMS CRITICAL TO STABILITY, SUCH AS BATTERIES, WITH ITEMS OF DIFFERENT WEIGHT OR SPECIFICATION. DO NOT MODIFY UNIT IN ANY WAY TO AFFECT STABILITY.
Is the replacement battery of equivalent voltage and amperage output as the OEM battery?
Battery Test
NOTE: Batteries in storage should be kept at 12.5V or higher.
Before testing for battery condition, the open circuit voltage should be taken from each battery. If the voltage of the batteries differs by 0.3 volts or more, the lower voltage battery should be replaced.
Battery Testing Can Be Performed In Two Ways:
1. The batteries can be tested using a battery tester capable of testing 12V 100Ah AGM VRLA (Valve Regulated Lead Acid) batteries, using the instructions of the battery tester manufacturer.
2. If an appropriate battery tester is unavailable, the batteries can be tested by fully charging them withthe charger that is installed on the machine. Then check the battery voltage of each battery - 4 hours - after charging is complete. Batteries less than 12.72 volts should be replaced.
NOTE: If a faulty charger is suspected, the batteries can be charged using a charger that supplies 2.45 volts/cell.
Charging should be terminated when the charge current drops below 1 amp.;
Access the parts list for your equipment in MaintainX.
Anerobic Thread Locking Compound, High Strength (Red)
0100019
Anerobic Thread Locking Compound, Medium - High Strength (Red)
0100071
Anerobic Thread Locking Compound, Medium Strength (Blue)
0100011
Battery
0400242
Cable Clamp Assembly Kit
7023275
Anerobic Thread Locking Compound, High Strength (Red)
0100019
Anerobic Thread Locking Compound, Medium - High Strength (Red)
0100071
Anerobic Thread Locking Compound, Medium Strength (Blue)
0100011
Battery
0400242
Cable Clamp Assembly Kit
7023275
Anerobic Thread Locking Compound, High Strength (Red)
0100019
Anerobic Thread Locking Compound, Medium - High Strength (Red)
0100071
Anerobic Thread Locking Compound, Medium Strength (Blue)
0100011
Battery
0400242
Cable Clamp Assembly Kit
7023275
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX