MaintainX Asset Hub logo
EnterprisePricing
Hyster

Hyster Forklift RS46-41S CH

Need answers fast?
Explore the manual using AI.

Hyster Forklift RS46-41S CH
Hyster Forklift RS46-41S CH

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Hyster Forklift RS46-41S CH

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Hyster Forklift RS46-41S CH

Hyster Forklift RS46-41S CH

Create an account to install this asset package.

Maintenance Plans for Hyster Forklift Model RS46-41S CH

Integrate maintenance plans directly into your work orders in MaintainX.

Boom Extension Circuit Assemble

Check mark

New seals installed

Check mark

Component/valve lubricated with clean hydraulic oil

Check mark

Temporary plug removed

Check mark

Component/valve or switch installed and torqued to value listed in the Torque Specifications

Check mark

Sign off on the Boom Extension Circuit Assemble

Run this procedureArrow right

Boom Extension Circuit Disassemble

Check mark

NOTE: Only use plugs that have been cleaned in solvent.

Check mark

NOTE: In the event that seals are missing, check manifold for missing seals and remove.

Check mark

NOTE: Cartridge valves are not field serviceable with exception of external seals and electrical solenoids. In event of a defective component, completely replace valve.

Check mark

NOTE: Check load holding valve for cracks. If there are cracks in load holding valve, the load holding valve must be replaced.

Check mark

The valve seals are serviceable parts of the load holding valve. Use the following procedures for repair:

Check mark

Unscrew the cartridge valve from the load holding valve. See Figure 9.

Check mark

Check that all seals are attached to cartridge valve.

Check mark

Install a temporary plug in place of cartridge valve.

Check mark

Upload a photo of the disassembled circuit

Run this procedureArrow right

Boom Extension Circuit Installation

Check mark

Position the load holding valve on the derricking cylinder.

Check mark

Install the four capscrews that fasten the load holding valve onto the derricking cylinder.

Check mark

Remove caps and connect the hydraulic lines to the load holding valve according to the identification tags made during removal.

Check mark

Connect the electrical wires to the load holding valve according to the identification tags made during removal.

Check mark

Warning: Do not try to locate hydraulic leaks by putting hands on pressurized hydraulic components. Hydraulic oil can be injected into the body by pressure.

Check mark

Caution: Never start the engine with closed shutoff valves. Open the shutoff valves before starting the engine to prevent damage to hydraulic components.

Check mark

Start the engine and operate the hydraulic system. Check that functions of the load holding valve work correctly. Check for any leaks.

Check mark

Did the load holding valve work correctly?

Check mark

Any leaks detected?

Run this procedureArrow right

Boom Extension Circuit Maintenance

Check mark

!WARNING: Cleaning solvents can be flammable and toxic and can cause skin irritation. When using cleaning solvents, always follow the solvent manufacturer’s recommended safety precautions.

Check mark

Compressed air can move particles and cause injury to the user or to other personnel. Verify compressed air path is away from all personnel. Wear eye protection.

Check mark

Clean cartridge valve in solvent and carefully dry the parts with compressed air.

Check mark

Inspect the bores for damage. If there are scratches or other damage, the load holding valve must be replaced.

Check mark

Inspect the fittings, O-rings, and check valves for damage. Replace damaged parts.

Check mark

Sign off on the Boom Extension Circuit Maintenance

Run this procedureArrow right

Boom Extension Circuit Removal

Check mark

!WARNING: Lower boom completely before working on control valve or hydraulic system. The boom can lower suddenly and cause injury if the boom is not lowered. This procedure will make sure that the boom cannot lower suddenly and cause injury or death.

Check mark

!NOTE: All valves, and other associated items installed on the load holding valve can be replaced. Before removal of any part, check that the area is clean and protected against dirt and fluid contamination.

Check mark

Place the truck on a solid and level surface.

Check mark

Lower boom and close the shutoff valves at the bottom of the hydraulic tank platform.

Check mark

Shut down the engine.

Check mark

!WARNING: Move all control levers back and forth a minimum of 20 times to remove all hydraulic pressure from pilot system.

Check mark

Put tags for identification on electrical wires. Disconnect the electrical wires from the load holding valve.

Check mark

Put tags for identification on hydraulic lines. Disconnect the hydraulic lines from the load holding valve. Put caps on the open lines, ports or other connectors.

Check mark

Remove the four capscrews that fasten the load holding valve to the rear side of the outer boom.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Hyster

Explore Other Assets