  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Hussmann Island and Multi-deck Island RI3

Hussmann Island and Multi-deck Island RI3

Create an account to install this asset package.

Maintenance Plans for Hussmann Island and Multi-deck Island Model RI3

Integrate maintenance plans directly into your work orders in MaintainX.

12 Monthly Center Air Discharge Tower Cleaning

Check mark

Warning: This cleaning procedure requires a trained technician!

Check mark

Product removed to cooler?

Check mark

Electrical power to the merchandiser disconnected?

Check mark

Shelves, display racks, deck pans, CAD gusset, and canopy light channel removed?

Check mark

Panels attached to CAD tower removed?

Check mark

Waste outlets verified open and drip piping not blocked? Loose debris removed?

Check mark

Unpressurized stream of water used to wash baffles in the CAD tower?

Check mark

Coil and fans cleaned as necessary?

Check mark

All surfaces clean and dry, reassembled in reverse order?

Run this procedureArrow right

1 Monthly Center Air Discharge Tower Cleaning

Check mark

CLEANING CENTER AIR DISCHARGE (CAD) TOWER

Check mark

The interior of the CAD tower must be cleaned at least monthly. Frequency is dependent on the ambient conditions of the store.

Check mark

Remove product to cooler

Check mark

DISCONNECT THE ELECTRICAL POWER TO THE MERCHANDISER

Check mark

Apply compressed air to the moiré (pattern of slots) of the CAD to blow accumulated dust off the internal baffles

Check mark

Use a soft cloth to wipe down the interior. A mild detergent and sanitizing solution may be used. Do not introduce excess water

Check mark

Turn on power to merchandiser

Check mark

Once operating temperature is reached, return product from cooler

Check mark

If air cleaning is not done at least monthly, Hussmann recommends washing by a technician at least every 4 months

Run this procedureArrow right

1 Weekly Merchandiser Cleaning

Check mark

CARE AND CLEANING

Check mark

WARNING: ALWAYS SHUT POWER OFF DURING CLEANING PROCESS.

Check mark

Fans shut off at the source

Check mark

All deck pans and air grilles removed

Check mark

CAUTION: Coil fins are sharp and pose risk of bodily injury - use extreme care when cleaning around them.

Check mark

Exterior surfaces cleaned with a mild detergent and warm water

Check mark

Interior surfaces cleaned with domestic detergents and sanitizing solutions

Check mark

WARNING: Do NOT allow product to sit in a non-refrigerated area.

Check mark

Product and all loose debris removed

Run this procedureArrow right

Drain Fitting Replacement

Check mark

Warning: Always disconnect the electrical power at the main disconnect when servicing or replacing any electrical component.

Check mark

Drill with a 17/8-in. (48 mm) hole saw to drill out the bottom of the drain fitting. Did you drill completely through fitting and bottom liner?

Check mark

Apply teflon tape to threaded end of adapter and screw into threaded end of tee. Was this done correctly?

Check mark

Apply an ABS and PVC compatible primer and sealer to adapter and inside of drain. Insert adapter into drain fitting. Was this done correctly?

Check mark

Sign off on the drain fitting replacement

Run this procedureArrow right

Electronic Ballasts Replacement

Check mark

WARNING: Always disconnect the electrical power at the main disconnect when servicing or replacing any electrical component. This includes, but is not limited to, such items as fans, heaters, thermostats and lights.

Check mark

Power to the merchandiser disconnected

Check mark

Side splashguard and base panels removed

Check mark

Ballast replaced and parts reassembled in reverse order

Check mark

Electrical power reconnected

Check mark

Sign off on the ballast replacement

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Hussmann

Explore Other Assets