The Graco Pump System 24F097 is a high-performance industrial pump designed for efficient fluid transfer and management. Known for its reliability and durability, this pump system is ideal for various applications in manufacturing and processing environments. Optimize your operations with the trusted Graco brand.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Graco Pump System 24F097
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Air Filter Maintenance
⚠️ Removing a pressurized air filter bowl could cause serious injury. Depressurize air line before servicing.
Pump systems have two air filters: the 5 micron air manifold filter (209) and the 40 micron pump air filter (206). Meter systems have only the 5 micron filter (209). Check filters daily and replace element(s) as needed. Order 15D909 (5 micron) or 15D890 (40 micron).
Close main air shutoff valve on air supply line and on system. Depressurize air line.
Remove the filter cover (A).
Unscrew the filter bowl (B).
Remove and replace element (206a, 209a).
Screw filter bowl (B) on securely. Install cover (A).
Note: Check Fluid Filter Daily.
Advanced Fluid Control Module (AFCM) Replacement
Follow Before Servicing, page 13. Disconnect main power.
Control Box opened
All cables from AFCM (302) removed
Note of cable locations
Ground wire disconnected from ground screw (GS)
Four mounting screws (303) loosened
AFCM slid up and out of keyhole slots
Follow steps in reverse order to install a new AFCM. See electrical schematic for cable connection information.
Follow instructions in Manual 3A1244 to update the software on the new AFCM.
Air Controls Maintenance
Remove Air Control Assembly
1. Follow Before Servicing, page 13.
2. See Fig. 17. Disconnect pump air lines, main air line, and solenoid air line.
NOTE: You may prefer to remove the A side air motor air line after you remove the assembly from the frame.
3. Loosen four screws (8) from sides of frame. Slide the assembly up and out to remove.
4. Follow steps in reverse order to reinstall air control assembly after repair.
Replace Pressure Gauge(s)
1. See Remove Air Control Assembly, page 22.
See FIG. 18, page 23, for a full diagram of the pump air controls.
Alarm Replacement
Follow Before Servicing, page 13. Disconnect main power.
Control Box opened
Alarm wires disconnected from alarm (311)
Alarm jam/mounting nut unscrewed and alarm removed
New alarm assembled and alarm wires reconnected
Control Box closed and power restored
Alternator Regulator Replacement
Follow Before Servicing, page 13. Disconnect main air.
Open Control Box.
Disconnect supply air line from regulator assembly (505).
Loosen air regulator swivel fittings (506) and remove from solenoid module.
Repair or replace alternator regulator parts as necessary. See Alternator Power Assembly, page 46, for repair parts. Replace air regulator swivel fitting (506).
Set regulator air pressure to 18 psi (0.12 MPa, 1.2 bar).
NOTICE: To avoid damage to the alternator, do not set the regulator air pressure higher than 18 psi (0.12 MPa, 1.2 bar).
Close Control Box and restore power.
Sign off on the alternator regulator replacement
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX