The Graco Meter System 24F081 is a high-performance industrial metering solution designed for precise fluid measurement and control. This reliable OEM asset enhances operational efficiency and accuracy in various applications, making it essential for effective fluid management in industrial settings.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Graco Meter System 24F081
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Air Filter Maintenance
⚠️ Removing a pressurized air filter bowl could cause serious injury. Depressurize air line before servicing.
Pump systems have two air filters: the 5 micron air manifold filter (209) and the 40 micron pump air filter (206). Meter systems have only the 5 micron filter (209). Check filters daily and replace element(s) as needed. Order 15D909 (5 micron) or 15D890 (40 micron).
Close main air shutoff valve on air supply line and on system. Depressurize air line.
Remove the filter cover (A).
Unscrew the filter bowl (B).
Remove and replace element (206a, 209a).
Screw filter bowl (B) on securely. Install cover (A).
Note: Check Fluid Filter Daily.
Sign off on the air filter maintenance
Advanced Fluid Control Module (AFCM) Replacement
Follow Before Servicing, page 13. Disconnect main power.
Control Box opened
All cables from AFCM (302) removed
Note of cable locations
Ground wire disconnected from ground screw (GS)
Four mounting screws (303) loosened
AFCM slid up and out of keyhole slots
Follow steps in reverse order to install a new AFCM. See electrical schematic for cable connection information.
Follow instructions in Manual 3A1244 to update the software on the new AFCM.
Air Controls Maintenance
Remove Air/Fluid Panel
1. Follow Before Servicing, page 13.
2. Disconnect main air line and solenoid air line. Disconnect fluid lines where they enter the valve stacks.
3. Remove four screws (8) from sides of frame.
4. Remove air/fluid panel assembly.
5. Follow steps in reverse order to reinstall assembly after repair.
Replace Ball Valve
1. See Remove Air/Fluid Panel, page 23.
2. Remove screw (106b) and washer (106c) from the handle on the front of the panel.
Alarm Replacement
Follow Before Servicing, page 13. Disconnect main power.
Control Box opened
Alarm wires disconnected from alarm (311)
Alarm jam/mounting nut unscrewed and alarm removed
New alarm assembled and alarm wires reconnected
Control Box closed and power restored
Alternator Regulator Replacement
Follow Before Servicing, page 13. Disconnect main air.
Control Box opened
Supply air line disconnected from regulator assembly (505)
Air regulator swivel fittings (506) loosened and removed from solenoid module
Alternator regulator parts repaired or replaced as necessary. Air regulator swivel fitting (506) replaced
Set regulator air pressure to 18 psi (0.12 MPa, 1.2 bar)
NOTICE: To avoid damage to the alternator, do not set the regulator air pressure higher than 18 psi (0.12 MPa, 1.2 bar)
Control Box closed and power restored
Sign off on the alternator regulator replacement
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX