MaintainX Asset Hub logo
EnterprisePricing
Goulds Pumps

Goulds Pumps Pump 3355 1.5 x 2.5-7A-3600

Need answers fast?
Explore the manual using AI.

Goulds Pumps Pump 3355 1.5 x 2.5-7A-3600
Goulds Pumps Pump 3355 1.5 x 2.5-7A-3600

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Goulds Pumps Pump 3355 1.5 x 2.5-7A-3600

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Goulds Pumps Pump 3355 1.5 x 2.5-7A-3600

Goulds Pumps Pump 3355 1.5 x 2.5-7A-3600

Create an account to install this asset package.

Maintenance Plans for Goulds Pumps Pump Model 3355 1.5 x 2.5-7A-3600

Integrate maintenance plans directly into your work orders in MaintainX.

3 Monthly Pump Alignment Inspection

Check mark

6.1 Maintenance schedule — Three-month inspections

Check mark

Check that the foundation and the hold-down bolts are tight

Check mark

Check the shaft alignment

Check mark

Realign the shaft if required

Check mark

Shorten the inspection intervals if the pumped fluid is abrasive or corrosive or if the environment is classified as potentially explosive

Run this procedureArrow right

1 Yearly Pump Performance Inspection

Check mark

6.1 Maintenance schedule — Annual inspections

Check mark

Enter the pump capacity

Check mark

Enter the pump pressure

Check mark

Enter the pump power

Check mark

Does the pump performance satisfy the process requirements?

Check mark

If the pump performance does not satisfy the process requirements, and the process requirements have not changed, then disassemble the pump, inspect it, and replace worn parts.

Check mark

Is the pumped fluid abrasive or corrosive, or is the environment classified as potentially explosive?

Check mark

If yes, describe how you will shorten the inspection intervals

Run this procedureArrow right

Mechanical Seal Inspection

Check mark

Mechanical-seal maintenance

Check mark

Check the seal and all flush piping before starting the pump

Check mark

Ensure the cleanliness of the pumped fluid

Check mark

Verify the type of mechanical seal used

Check mark

Disengage holding clips for cartridge seals installed by the user

Check mark

Keep the manufacturer's reference drawing for future maintenance

Check mark

Verify the required flush fluid and attachment points as per the seal drawing

Check mark

Is the mechanical seal operating without any leaks?

Check mark

Describe any issues found during the inspection

Run this procedureArrow right

Coupling Alignment Check

Check mark

4.3.1 Alignment checks

Check mark

Perform alignment checks under these circumstances

Check mark

Enter the Total Indicated Reading (T.I.R.) at operating temperature

Check mark

Enter the tolerance of the indicator

Check mark

4.3.3 Alignment measurement guidelines

Check mark

Rotate the pump coupling half and the driver coupling half together so that the indicator rods have contact with the same points on the driver coupling half.

Check mark

Move or shim only the driver to make adjustments.

Check mark

Are the hold-down bolts for the driver tight when taking indicator measurements?

Check mark

Are the hold-down bolts for the driver loose before making alignment corrections?

Run this procedureArrow right

3800 Hourly Ball Bearing Lubrication

Check mark

Grease lubrication schedule

Check mark

Re-lubrication intervals by speed

Check mark

Enter the actual operating speed (rpm)

Check mark

Enter the grease quantity for suction side (oz)

Check mark

Enter the grease quantity for discharge side (oz)

Check mark

Lubricating-grease requirements

Check mark

Select the grease type used

Check mark

Is the temperature of pumped fluid less than 177°C | 350°F?

Check mark

Was the rotor and old grease removed before regreasing?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Goulds Pumps

Explore Other Assets