Fresenius Medical Care North America Crit-Line In Clip Device CLIC
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
CLiC Device Cleaning
Preparation
Prepare a freshly diluted bleach solution (1:100) or other suitable hospital disinfectant.
Ensure all cleaning materials are non-abrasive and free of solvents.
Cleaning the Exterior
Clean the exterior of the following components with a cloth dampened with the cleaning solution
Ensure no liquid infiltrates the CLiC device during cleaning.
Post-Cleaning Inspection
Inspect the CLiC device for any signs of liquid infiltration or damage.
Check the verification filter for scratches or damage.
CLiC Device Calibration
Preparation
Verify if calibration is needed by checking if verification fails in Dialysis Mode.
Plug the CLiC device USB cable into the USB port on the right side of the 2008T hemodialysis machine display screen.
Power on the 2008T hemodialysis machine into Service Mode and go to the 'Maint.' screen.
Calibration Process
Select the Crit-Line Calibration screen-button to enter the 'Crit-Line Calibration' screen.
Wait for the message 'Initializing CLiC ... ' to clear.
Attach the CLiC device to the verification filter on its USB cable.
Enter the serial number printed on the verification filter (case-sensitive).
Access the parts list for your equipment in MaintainX.
CLiC Device
CL10041001
Crit-Line Blood Chamber
CL10041021
Combiset SMARTECH Blood Tubing Set W/ Heparin Line
03-2722-9C
Combiset SMARTECH Blood Tubing Set W/O Heparin Line
03-2742-9C
CLiC Holder
290760
CLiC Device
CL10041001
Crit-Line Blood Chamber
CL10041021
Combiset SMARTECH Blood Tubing Set W/ Heparin Line
03-2722-9C
Combiset SMARTECH Blood Tubing Set W/O Heparin Line
03-2742-9C
CLiC Holder
290760
CLiC Device
CL10041001
Crit-Line Blood Chamber
CL10041021
Combiset SMARTECH Blood Tubing Set W/ Heparin Line
03-2722-9C
Combiset SMARTECH Blood Tubing Set W/O Heparin Line
03-2742-9C
CLiC Holder
290760
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX