Fisher Scientific Benchtop Meter AB150
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Benchtop Meter Calibration
Preparation
Ensure the conductivity electrode is soaked in alcohol or clean water if it has been stored dry.
Turn meter on and select the appropriate mode using MODE button.
Single Point Calibration
Rinse the electrode with clean water.
Submerse the electrode in the first conductivity standard.
Press STD to enter standardization mode.
Is 'Stable' displayed on the meter?
Adjust the cell constant manually or keep the nominal value?
Benchtop Meter mV Calibration
Preparation
Turn meter on and connect a combination ORP electrode
Press MODE if needed for mV (or R.mV) measurement
Calibration Process
Select the solution with a known mV value
Dip the ORP electrode into the solution with brief or slow stirring
Press STD to begin standardization
Adjust the value using ▲/▼ keys
Press STD when the reading is stable to accept the calibration offset
Benchtop Meter Temperature Calibration
Preparation
Ensure the following conditions are met before starting
Calibration Procedure
Connect the temperature probe and place into a solution with a known accurate temperature
Is the temperature probe part of a pH or Conductivity electrode?
Ensure the AB200 temperature inputs are correctly connected
Is the reading stable?
Press STD from any measurement mode, then press TEMP STD
Record the active temperature from the upper display
Benchtop Meter Conductivity Calibration
Preparation
Turn meter on and set to conductivity measurement mode
Soak electrode in alcohol or clean water if stored dry for a long time
Single Point Calibration
Rinse electrode with clean water
Submerse electrode in conductivity standard
Provide stirring for best results
Press STD to enter standardization mode
Adjust cell constant manually using ▲/▼ keys?
Benchtop Meter pH Calibration
Preparation
Ensure periodic standardization with known accurate standards
Select pH calibration buffer group
Attach automatic temperature compensation (ATC) probe
Was the pH electrode stored dry?
Soak pH electrode in storage solution for 10 minutes if stored dry
Standardization with Preset Buffer Group
Turn meter on and set to pH measurement mode
Rinse pH and ATC electrodes with clean water
Access the parts list for your equipment in MaintainX.
Fisher Scientific Accumet Benchtop Stirring Probe
13-620-BSP
Replacement Paddle For 13-620-BSP
13-620-RP
PH/ATC Electrode, Double Junction, Plastic Body, Refillable
13-620-631
PH Electrode, Double Junction, Glass Body, Refillable
13-620-183A
PH Electrode, Single Junction, Glass Body, Refillable
13-620-285
Fisher Scientific Accumet Benchtop Stirring Probe
13-620-BSP
Replacement Paddle For 13-620-BSP
13-620-RP
PH/ATC Electrode, Double Junction, Plastic Body, Refillable
13-620-631
PH Electrode, Double Junction, Glass Body, Refillable
13-620-183A
PH Electrode, Single Junction, Glass Body, Refillable
13-620-285
Fisher Scientific Accumet Benchtop Stirring Probe
13-620-BSP
Replacement Paddle For 13-620-BSP
13-620-RP
PH/ATC Electrode, Double Junction, Plastic Body, Refillable
13-620-631
PH Electrode, Double Junction, Glass Body, Refillable
13-620-183A
PH Electrode, Single Junction, Glass Body, Refillable
13-620-285
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX