MaintainX Asset Hub logo
EnterprisePricing
Magnetrol International

Magnetrol International Level Switch 961-50A0-010

Need answers fast?
Explore the manual using AI.

Magnetrol International Level Switch 961-50A0-010
Magnetrol International Level Switch 961-50A0-010

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Magnetrol International Level Switch 961-50A0-010

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Magnetrol International Level Switch 961-50A0-010

Magnetrol International Level Switch 961-50A0-010

Create an account to install this asset package.

Maintenance Plans for Magnetrol International Level Switch Model 961-50A0-010

Integrate maintenance plans directly into your work orders in MaintainX.

Unit Check

Check mark

After unpacking and before installation, perform the following operational check on the unit in a non-hazardous area:

Check mark

1. Apply proper operating voltage to terminals L1 and L2/N. Power supply ground should be connected to the green ground screw in housing base.

Check mark

2. Fill a suitable container with liquid.

Check mark

3. Place transducer gap in the liquid. The relay output should actuate.

Check mark

4. Remove transducer from the liquid. The relay output should de-actuate. In case of malfunction, consult Section 3.1, Troubleshooting on page 7.

Check mark

⚠ Caution: This unit contains CMOS electronics which may become damaged by static electricity. Do not touch any semiconductor devices unless you are properly grounded.

Run this procedureArrow right

Switch Mounting

Check mark

The Model 961 level switch may be mounted in a variety of positions as shown in Figures 2 through 5. Model 962 is always mounted vertically.

Check mark

Proper orientation of the transducer gap will facilitate maximum performance in difficult applications. When the Model 961 is mounted horizontally, the transducer gap must be turned vertically to allow proper drainage of liquid out of the gap.

Check mark

The wrench flats on the mounting nut are aligned with the transducer gap; therefore, proper transducer mounting can be achieved by aligning the mounting nut flats in a vertical orientation. See Figure 4. For flanged transducers, a vertical gap orientation should be confirmed prior to installing unit to the mating flange.

Check mark

When installing a Model 961 switch in a nozzle or pipe, the transducer gap must extend into the tank at least one inch beyond the inside tank wall. Refer to Figure 5.

Check mark

Screw transducer into the opening using a wrench on the transducer mounting nut flats. If flanged, bolt unit to mating flange with proper gasket. Use thread tape or suitable pipe compound on the threads. Do not over-tighten.

Run this procedureArrow right

Parts for Magnetrol International Level Switch 961-50A0-010

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Cast Aluminum Cover Without Window

089-6607-005

Cast Aluminum Cover With Window

036-4410-010

Cast 316 SS Cover Without Window

089-6607-006

Deep Drawn SS Hygienic Cover Without Window

036-5702-003

Deep Drawn SS Hygienic Cover With Window

036-5702-002

Cast Aluminum Cover Without Window

089-6607-005

Cast Aluminum Cover With Window

036-4410-010

Cast 316 SS Cover Without Window

089-6607-006

Deep Drawn SS Hygienic Cover Without Window

036-5702-003

Deep Drawn SS Hygienic Cover With Window

036-5702-002

Cast Aluminum Cover Without Window

089-6607-005

Cast Aluminum Cover With Window

036-4410-010

Cast 316 SS Cover Without Window

089-6607-006

Deep Drawn SS Hygienic Cover Without Window

036-5702-003

Deep Drawn SS Hygienic Cover With Window

036-5702-002

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Magnetrol International

Explore Other Assets