PDF MANUAL

Manual for Doosan Portable Light Tower LSCWKUB-60HZ-T4F

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Doosan Portable Light Tower LSCWKUB-60HZ-T4F

Doosan Portable Light Tower LSCWKUB-60HZ-T4F

Create an account to install this asset package.

Maintenance Plans for Doosan Portable Light Tower Model LSCWKUB-60HZ-T4F

Integrate maintenance plans directly into your work orders in MaintainX.

1000 Hourly/12 Monthly Light Tower Maintenance

Check mark

Engine Shutdown System Switches (setting) Check

Check mark

Once a year, the Engine Coolant High Temperature Switch should be tested.

Check mark

Remove switch from the unit and place it in a bath of heated oil. The Engine Coolant High Temperature Switch will require a temperature of approximately 220°F (104°C) to actuate.

Check mark

NOTE: The Engine Temperature Switch does NOT offer protection when NO coolant is present.

Check mark

Test the switch operation by connecting an ohmmeter between the two wire terminals. The ohmmeter should show zero ohms.

Check mark

When the switch is placed in the heated oil bath and its contact closed, the ohmmeter should indicate zero ohms. Tap the switch lightly during the checking operation.

Check mark

Replace any defective switch before continuing to operate the unit.

Check mark

CAUTION: Never operate the unit with a defective safety shutdown switch or with a by-passed or disconnected switch.

Run this procedureArrow right

1000 Hourly Light Tower Service

Check mark

Starter - Inspect

Check mark

Alternator - Inspect

Check mark

Bolts and nuts on the engine - Retighten

Run this procedureArrow right

1 Daily Light Tower Maintenance

Check mark

Check for evidence of arcing around the electrical terminals.

Check mark

Check for loose wire routing clamps. Clamps must be secure and properly mounted. Also check wiring for wear, deterioration, and vibration abrasion.

Check mark

Engine Oil Level

Check mark

Coolant Level

Check mark

Check that the grounding circuit is in accordance with the National Electric Code Article 250 and the local code requirements. As a minimum, the wire size should be American Wire Gauge 8 (AWG#8) from the grounding terminal, when required. Check to ensure continuity between the grounding terminal, frame, generator, and engine block.

Check mark

Inspect the instrument lamps, gauges, and switches prior to start-up and during operation to ensure proper functioning.

Check mark

Check for loose or frayed wiring insulation or sleeving.

Check mark

Inspect Tower Cables for damaged areas.

Check mark

Clean the air vents of any obstructions or debris.

Run this procedureArrow right

1 Monthly Engine Coolant System Maintenance

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Is the coolant system filled with a 50/50 mixture of water and ethylene glycol?

Check mark

Brand of rust inhibitor used

Check mark

Freezing protection level of the coolant

Check mark

Is the radiator exterior free from obstructions, dirt, and debris?

Check mark

Did you blow water or compressed air containing a non-flammable solvent between the fins in a direction opposite the normal air flow?

Check mark

Is the radiator internally clogged?

Check mark

Commercial product used for reverse flushing

Check mark

Sign off on the engine coolant system maintenance

Run this procedureArrow right

1 Monthly Light Tower Maintenance

Check mark

Engine Radiator (exterior) Check

Check mark

Check the coolant level in the radiator. The coolant must cover the tubes in the top tank (approximately 1 inch high on a clean measuring rod, stuck down filler neck).

Check mark

Air Intake Hoses and Flexible Hoses Check

Check mark

All rubber hose joints and the screw type hose clamps must be tight and the hoses showing no signs of wear, abrasion, or deterioration.

Check mark

All flexible hoses must be free of wear, deterioration, and vibration abrasion. Routing clamps must be properly mounted and secure.

Check mark

Fasteners (tighten) Check

Check mark

Monthly spot check several capscrews and nuts for proper torque. If any are found loose, a more thorough inspection must be made and deficiencies corrected.

Check mark

Engine Protection Shutdown System Check

Check mark

The operation of the Engine Protection Shutdown System should be checked every month or whenever it appears not to be operating properly. The three switches involved in this protective shutdown system are the Engine Coolant High Temperature Switch, the Engine Oil Pressure Switch and the Low Fuel Switch.

Run this procedureArrow right

Parts for Doosan Portable Light Tower LSCWKUB-60HZ-T4F

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Filter Kit 250 Hours - LSCWKUB

46618979

Filter Kit 500 Hours - LSCWKUB

46618980

Filter Kit 250 Hours - LSCWKUB

46618979

Filter Kit 500 Hours - LSCWKUB

46618980

Filter Kit 250 Hours - LSCWKUB

46618979

Filter Kit 500 Hours - LSCWKUB

46618980

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll