Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Indoor Unit Multi-Split Type Air Conditioner FTXR18TVJUS
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Capacitor Voltage Check
Warning: Check the main circuit for short circuit before proceeding
Circuit breaker is still on
Warning: Never touch any live parts
Voltage between FU2 and DC–
Voltage is 50 V or less
Ensure firm contact between the multimeter probes and the test points
Sign off on the capacitor voltage check
Electronic Expansion Valve Check
Conduct the following to check the electronic expansion valve (EV).
1. Check if the EV connector is correctly inserted in the PCB. Match the EV unit number and the connector number.
2. Turn the power off and on again, and check if all the EVs generate a latching sound.
3. If any of the EVs does not generate a latching sound in the above step 2, disconnect that connector and check the continuity using a multimeter.
Check the continuity between the pins 5 - 1, 5 - 2, 5 - 3, 5 - 4. If there is no continuity between the pins, the EV coil is faulty.
4. If no EV generates a latching sound in the above step 2, the outdoor unit PCB is faulty.
5. If the continuity is confirmed in the above step 3, mount a good coil (which generated a latching sound) in the EV unit that did not generate a latching sound, and check if that EV generates a latching sound.
∗If a latching sound is generated, the outdoor unit PCB is faulty.
∗If a latching sound is not generated, the EV unit is faulty.
Hall IC Check
CDXS, FDXS Series
Check the connector connection
With the power on, operation off, and the connector connected, check the following
Output voltage of about 5 V between pins 1 and 3
Generation of 3 pulses between pins 2 and 3 when the indoor fan motor is operating
If NG in step (1)
If NG in step (2)
If OK in both steps (1) and (2)
Sign off on the Hall IC Check
Indoor Fan Motor Connector Check
CTXG, FTXR, CTXS, FTXS, FVXS Series
1. Check the connection of connector.
2. Check motor power supply voltage output (pins 4 - 7).
3. Check motor control voltage (pins 4 - 3).
4. Check rotation command voltage output (pins 4 - 2).
5. Check rotation pulse input (pins 4 - 1).
FDMQ Series
1. Turn the power supply OFF.
2. With the fan motor connector disconnected, measure the resistance between each pin, then make sure that the resistance is more than the value mentioned in the following table.
Inverter Analyzer Check
Warning: This procedure requires trained personnel with PPE!
Is the power turned off?
If power is not turned off, stop the procedure and turn off the power
Is the inverter analyzer installed instead of a compressor?
Warning: Ensure the charged voltage of the built-in smoothing electrolytic capacitor drops to 10 VDC or below before proceeding
Are the terminals (U,V,W) not touching each other?
Warning: High voltage is applied if terminals touch each other
Is the power transistor test operation activated from the outdoor unit?
Diagnose according to 6 LEDs lighting status
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX