MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Cooling-Only Outdoor Unit RKN09KEVJU

Need answers fast?
Explore the manual using AI.

Daikin Cooling-Only Outdoor Unit RKN09KEVJU
Daikin Cooling-Only Outdoor Unit RKN09KEVJU

The Daikin Cooling-Only Outdoor Unit RKN09KEVJU is a high-efficiency air conditioning solution designed for optimal cooling performance. This unit is ideal for residential and commercial applications, ensuring reliable operation and energy savings. Experience superior comfort with Daikin's advanced technology and robust design.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Cooling-Only Outdoor Unit RKN09KEVJU

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Cooling-Only Outdoor Unit RKN09KEVJU

Daikin Cooling-Only Outdoor Unit RKN09KEVJU

Create an account to install this asset package.

Maintenance Plans for Daikin Cooling-Only Outdoor Unit Model RKN09KEVJU

Integrate maintenance plans directly into your work orders in MaintainX.

Air Filter Removal

Check mark

Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. Appearance features

Check mark

Warning

Check mark

Dangerous: High voltage

Check mark

A high voltage is applied to all the electric circuits of this product including thermistors.

Check mark

When a signal from the remote controller is received, the receiving tone sounds and the operation lamp flickers immediately to confirm the signal reception.

Check mark

When the ON/OFF button is kept pressed for 5 seconds, the forced cooling operation is performed for about 15 minutes.

Check mark

2. Remove the air filters.

Check mark

1 Open the front panel to the position where it stops.

Run this procedureArrow right

Electrical Box / Vertical Blade Removal

Check mark

Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. Disconnect the connecting wires.

Check mark

Preparation

Check mark

 Remove the front grille according to the “Removal of Front Grille”.

Check mark

1 Remove the screw of the service cover.

Check mark

2 Pull out the service cover down in the direction of the arrow.

Check mark

3 The figure shows the connections of wire harnesses.

Check mark

4 Remove the screw of the wire retaining plate.

Check mark

5 Loosen the screws of the terminal board and disconnect the connecting wires.

Run this procedureArrow right

Electronic Expansion Valve Check

Check mark

EV connector correctly connected to the PCB

Check mark

EV generates latching sound when power is turned off and on

Check mark

Continuity confirmed when connector is disconnected and checked with a tester

Check mark

Check continuity between the pins

Check mark

EV coil is not faulty

Check mark

Outdoor unit PCB is not faulty

Check mark

Note: Latching sound varies depending on the valve type

Run this procedureArrow right

Fan Motor Connector Output Check

Check mark

FTXN15/18/24KVJU

Check mark

1. Check the connection of connector.

Check mark

2. Check the motor power supply voltage output (pins 4 - 7).

Check mark

3. Check the motor control voltage (pins 4 - 3).

Check mark

4. Check the rotation command voltage (pins 4 - 2).

Check mark

5. Check the rotation pulse (pins 4 - 1).

Check mark

FTXN09/12KEVJU

Check mark

Fan motor wire breakdown / short circuit check

Check mark

1. Check the connector for connection.

Run this procedureArrow right

Fan Rotor / Fan Motor Removal

Check mark

Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. Remove the right side panel.

Check mark

Preparation

Check mark

Remove the indoor heat exchanger according to the “Removal of Indoor Heat Exchanger”.

Check mark

1 Remove the screw of the right side panel.

Check mark

2 Unfasten the hook of the right side panel.

Check mark

3 Remove the right side panel.

Check mark

2. Remove the fan rotor and the fan motor.

Check mark

1 The fan motor has 3 projections on the right side.

Run this procedureArrow right

Parts for Daikin Cooling-Only Outdoor Unit RKN09KEVJU

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Checker

1225477

Silicon Grease

1172698

Inverter Checker

1225477

Silicon Grease

1172698

Inverter Checker

1225477

Silicon Grease

1172698

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets