The Daikin Outdoor Heat Pump RXN12KEVJU is a high-efficiency HVAC solution designed for residential and commercial applications. This model provides reliable heating and cooling performance, ensuring optimal indoor comfort while minimizing energy consumption. Ideal for various climates, it features advanced technology for enhanced durability and efficiency.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Outdoor Heat Pump RXN12KEVJU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Air Filter Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1. Appearance features
Warning
Dangerous: High voltage
A high voltage is applied to all the electric circuits of this product including thermistors.
When a signal from the remote controller is received, the receiving tone sounds and the operation lamp flickers immediately to confirm the signal reception.
When the ON/OFF button is kept pressed for 5 seconds, the forced cooling operation is performed for about 15 minutes.
2. Remove the air filters.
1 Open the front panel to the position where it stops.
Electrical Box / Vertical Blade Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1. Disconnect the connecting wires.
Preparation
Remove the front grille according to the “Removal of Front Grille”.
1 Remove the screw of the service cover.
2 Pull out the service cover down in the direction of the arrow.
3 The figure shows the connections of wire harnesses.
4 Remove the screw of the wire retaining plate.
5 Loosen the screws of the terminal board and disconnect the connecting wires.
Electronic Expansion Valve Check
EV connector correctly connected to the PCB
EV generates latching sound when power is turned off and on
Continuity confirmed when connector is disconnected and checked with a tester
Check continuity between the pins
EV coil is not faulty
Outdoor unit PCB is not faulty
Note: Latching sound varies depending on the valve type
Fan Motor Connector Output Check
FTXN15/18/24KVJU
1. Check the connection of connector.
2. Check the motor power supply voltage output (pins 4 - 7).
3. Check the motor control voltage (pins 4 - 3).
4. Check the rotation command voltage (pins 4 - 2).
5. Check the rotation pulse (pins 4 - 1).
FTXN09/12KEVJU
Fan motor wire breakdown / short circuit check
1. Check the connector for connection.
Fan Rotor / Fan Motor Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1. Remove the right side panel.
Preparation
Remove the indoor heat exchanger according to the “Removal of Indoor Heat Exchanger”.
1 Remove the screw of the right side panel.
2 Unfasten the hook of the right side panel.
3 Remove the right side panel.
2. Remove the fan rotor and the fan motor.
1 The fan motor has 3 projections on the right side.
Access the parts list for your equipment in MaintainX.
Inverter Checker
1225477
Silicon Grease
1172698
Inverter Checker
1225477
Silicon Grease
1172698
Inverter Checker
1225477
Silicon Grease
1172698
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX