Daikin Outdoor Heat Pump RXN18KEVJU

The Daikin Outdoor Heat Pump RXN18KEVJU is a high-efficiency HVAC solution designed for reliable heating and cooling. This model features advanced technology for optimal performance, making it ideal for residential and commercial applications. Experience energy savings and comfort with Daikin's trusted outdoor heat pump systems.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Outdoor Heat Pump RXN18KEVJU

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Outdoor Heat Pump RXN18KEVJU

Daikin Outdoor Heat Pump RXN18KEVJU

Create an account to install this asset package.

Maintenance Plans for Daikin Outdoor Heat Pump Model RXN18KEVJU

Integrate maintenance plans directly into your work orders in MaintainX.

Air Filter / Front Panel Removal

Check mark

Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Warning: Dangerous: High voltage

Check mark

A high voltage is applied to all the electric circuits of this product including thermistors.

Check mark

When the signal receiver catches a signal from the remote controller, the receiving tone sounds and the operation lamp blinks immediately to confirm the signal reception.

Check mark

When the ON/OFF button is kept pressed for 5 seconds, the forced cooling operation is performed for about 15 minutes.

Check mark

1. Remove the air filters.

Check mark

1 Open the front panel to the position where it stops.

Check mark

2 Slightly push up the center knob of the air filter and unfasten the hooks.

Check mark

3 Pull out the air filter downward and remove it.

Run this procedureArrow right

Electrical Box / PCB / Swing Motor Removal

Check mark

Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. Remove the electrical box.

Check mark

Preparation

Check mark

Remove the front grille according to the “Removal of Front Grille”.

Check mark

1 Remove the screw and remove the drip proof plate.

Check mark

2 Cut the clamp.

Check mark

3 Pull out the indoor heat exchanger thermistor.

Check mark

4 Remove the screw of the ground.

Check mark

5 Remove the screws of the connection wires.

Run this procedureArrow right

Electronic Expansion Valve Check

Check mark

EV connector correctly connected to the PCB

Check mark

EV generates latching sound when power is turned off and on

Check mark

Continuity confirmed when connector is disconnected and checked with a tester

Check mark

Check continuity between the pins

Check mark

EV coil is not faulty

Check mark

Outdoor unit PCB is not faulty

Check mark

Note: The latching sound varies depending on the valve type

Check mark

Sign off on the electronic expansion valve check

Run this procedureArrow right

Fan Motor Connector Output Check

Check mark

FTXN15/18/24KVJU

Check mark

1. Check the connection of connector.

Check mark

2. Check the motor power supply voltage output (pins 4 - 7).

Check mark

3. Check the motor control voltage (pins 4 - 3).

Check mark

4. Check the rotation command voltage (pins 4 - 2).

Check mark

5. Check the rotation pulse (pins 4 - 1).

Check mark

FTXN09/12KEVJU

Check mark

Fan motor wire breakdown / short circuit check

Check mark

1. Check the connector for connection.

Run this procedureArrow right

Fan Motor / Fan Rotor Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Right side plate removed

Check mark

Fan motor and rotor removed

Check mark

Enter the play between the side face of the rotor and the bottom frame in mm

Check mark

Fan motor and the fan rotor reassembled correctly

Check mark

Fan rotor removed

Check mark

Left side plate removed

Check mark

Bearing removed

Check mark

Sign off on the fan motor / fan rotor removal

Run this procedureArrow right

Parts for Daikin Outdoor Heat Pump RXN18KEVJU

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Checker

1225477

Silicon Grease

1172698

Inverter Checker

1225477

Silicon Grease

1172698

Inverter Checker

1225477

Silicon Grease

1172698

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets