The Daikin Outdoor Heat Pump RXN24KEVJU is a high-efficiency HVAC solution designed for optimal heating and cooling performance. This model features advanced technology for energy savings and reliable operation, making it ideal for residential and commercial applications. Experience superior comfort with Daikin's innovative outdoor heat pump systems.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Outdoor Heat Pump RXN24KEVJU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Air Filter / Front Panel Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Warning: Dangerous: High voltage
A high voltage is applied to all the electric circuits of this product including thermistors.
When the signal receiver catches a signal from the remote controller, the receiving tone sounds and the operation lamp blinks immediately to confirm the signal reception.
When the ON/OFF button is kept pressed for 5 seconds, the forced cooling operation is performed for about 15 minutes.
1. Remove the air filters.
1 Open the front panel to the position where it stops.
2 Slightly push up the center knob of the air filter and unfasten the hooks.
3 Pull out the air filter downward and remove it.
Electrical Box / PCB / Swing Motor Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1. Remove the electrical box.
Preparation
Remove the front grille according to the “Removal of Front Grille”.
1 Remove the screw and remove the drip proof plate.
2 Cut the clamp.
3 Pull out the indoor heat exchanger thermistor.
4 Remove the screw of the ground.
5 Remove the screws of the connection wires.
Electronic Expansion Valve Check
EV connector correctly connected to the PCB
EV generates latching sound when power is turned off and on
Continuity present when connector is disconnected and checked with a tester
Check continuity between the following pins
EV coil is not faulty if there is continuity between the pins
Outdoor unit PCB is not faulty if continuity is confirmed
Note: Latching sound varies depending on the valve type
Sign off on the electronic expansion valve check
Fan Motor Connector Output Check
FTXN15/18/24KVJU
1. Check the connection of connector.
2. Check the motor power supply voltage output (pins 4 - 7).
3. Check the motor control voltage (pins 4 - 3).
4. Check the rotation command voltage (pins 4 - 2).
5. Check the rotation pulse (pins 4 - 1).
FTXN09/12KEVJU
Fan motor wire breakdown / short circuit check
1. Check the connector for connection.
Fan Motor / Fan Rotor Removal
Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Right side plate removed
Fan motor and rotor removed
Enter the distance between the side face of the rotor and the bottom frame in mm
Fan motor and the fan rotor reassembled correctly
Fan rotor removed
Left side plate removed
Bearing removed
Sign off on the fan motor / fan rotor removal
Access the parts list for your equipment in MaintainX.
Inverter Checker
1225477
Silicon Grease
1172698
Inverter Checker
1225477
Silicon Grease
1172698
Inverter Checker
1225477
Silicon Grease
1172698
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX