Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Screw Chiller AWV016
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Screw Chiller Lubrication
Warning: Handle POE oil carefully using proper protective equipment (gloves, eye protection, etc.).
Fan motor bearings noise check
CAUTION: Avoid prolonged exposure of refrigerant to the atmosphere to prevent moisture absorption.
Select the type of POE oil used
Compressor oil heater is on when the compressor is off and off when the compressor is on?
Sign off on the screw chiller lubrication
1 Weekly Screw Chiller Maintenance
General
Complete unit log and review. Log readings can be taken daily for a higher level of unit observation.
Electrical ( * including the VFDs)
Clean control box fan filter. The weekly fan filter cleaning schedule can be modified to meet job conditions. It is important that the filter allows full air flow.
Refrigeration/Lubricant
Check liquid line sight glasses for clear flow
Check compressor oil sight glass for correct level (lubricant charge);
Oil Filter Disassembling
Prior to this procedure, pump out the compressor. Isolate the electrical supply to the control panels and compressor motor terminal. Filter should be changed when pressure drop delta goes above the linear line in Figure 74.
WARNING:
After the compressor has been pumped down and isolated, the oil contained inside the filter housing will remain hot enough to cause burns for some time afterwards. Always allow sufficient time for the oil to cool down so that it is cool enough not to be a danger when drained off (less than 35°C is recommended). Severe injury from burns can result.
Oil filter assembly components are:
- Oil Filter – 250mm
- Oil Filter Housing Cover
- O-Ring – 89.5x3
- O-Ring – 76.1x3.4
- (6) M8 Bolts
Screw Chiller Pre-Startup Inspection
Inspect the chiller to ensure no components became loose or damaged during shipping or installation, including leak test and wiring check.
Discharge shutoff valve and the optional compressor suction butterfly valves are open?
Manual liquid line shutoff valves at the outlet of the subcooler coils are open?
Leaving chilled water temperature set point on the MicroTech® III controller
Auxiliary equipment for the installation started by turning on the time clock, and/or remote on/off switch, and chilled water pump?
Pumpdown switches Q1 and Q2 are in the “Pumpdown and Stop” (open) position?
S1 switch is in the “Auto” position?
Under the “Control Mode” menu of the keypad, is the unit in the automatic Cool Mode?
System started by moving pumpdown switch Q1 to the “Auto” position?
Oil Filter Assembling
Prior to this procedure, pump out the compressor. Isolate the electrical supply to the control panels and compressor motor terminal. Filter should be changed when pressure drop delta goes above the linear line in Figure 74.
WARNING:
After the compressor has been pumped down and isolated, the oil contained inside the filter housing will remain hot enough to cause burns for some time afterwards. Always allow sufficient time for the oil to cool down so that it is cool enough not to be a danger when drained off (less than 35°C is recommended). Severe injury from burns can result.
Oil filter assembly components are:
- Oil Filter – 250mm
- Oil Filter Housing Cover
- O-Ring – 89.5x3
- O-Ring – 76.1x3.4
- (6) M8 Bolts
Access the parts list for your equipment in MaintainX.
AWG Wire Gauge
83754
AWG Wire
83804
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
AWG Wire Gauge
83754
AWG Wire
83804
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
AWG Wire Gauge
83754
AWG Wire
83804
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX