Daikin Screw Chiller AWV022
Daikin Screw Chiller AWV022

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Screw Chiller AWV022

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Screw Chiller AWV022

Daikin Screw Chiller AWV022

Create an account to install this asset package.

Maintenance Plans for Daikin Screw Chiller Model AWV022

Integrate maintenance plans directly into your work orders in MaintainX.

Oil Filter Assembling

Check mark

Prior to this procedure, pump out the compressor. Isolate the electrical supply to the control panels and compressor motor terminal. Filter should be changed when pressure drop delta goes above the linear line in Figure 74.

Check mark

WARNING:

Check mark

After the compressor has been pumped down and isolated, the oil contained inside the filter housing will remain hot enough to cause burns for some time afterwards. Always allow sufficient time for the oil to cool down so that it is cool enough not to be a danger when drained off (less than 35°C is recommended). Severe injury from burns can result.

Check mark

Oil filter assembly components are:

Check mark

- Oil Filter – 250mm

Check mark

- Oil Filter Housing Cover

Check mark

- O-Ring – 89.5x3

Check mark

- O-Ring – 76.1x3.4

Check mark

- (6) M8 Bolts

Run this procedureArrow right

Electrical Terminals Check

Check mark

DANGER: Electric equipment can cause electric shock which will cause severe personal injury or death. Turn off, lock out and tag all power before continuing with following service. Panels can have more than one power source.

Check mark

CAUTION: Periodically check electrical terminals for tightness and tighten as required. Always use a backup wrench when tightening electrical terminals.

Check mark

Power turned off, locked out and tagged?

Check mark

Checked electrical terminals for tightness?

Check mark

Used a backup wrench when tightening electrical terminals?

Check mark

Sign off on the electrical terminals check

Run this procedureArrow right

1 Weekly Screw Chiller Maintenance

Check mark

General

Check mark

Complete unit log and review. Log readings can be taken daily for a higher level of unit observation.

Check mark

Electrical (including the VFDs)

Check mark

Clean control box fan filter. The weekly fan filter cleaning schedule can be modified to meet job conditions. It is important that the filter allows full air flow.

Check mark

Refrigeration/Lubricant

Check mark

Check liquid line sight glasses for clear flow

Check mark

Check compressor oil sight glass for correct level (lubricant charge);

Run this procedureArrow right

1 Monthly Screw Chiller Maintenance

Check mark

Monthly operations include all weekly operations.

Check mark

General:

Check mark

- Inspect unit for loose or damaged components and visible leaks

Check mark

Electrical ( * including the VFDs):

Check mark

- Visually inspect components for signs of overheating

Check mark

- Verify compressor and oil heater operation

Check mark

Refrigeration/Lubricant:

Check mark

- Leak test

Check mark

- Check filter-drier pressure drop. Replace the filter if pressure drop exceeds 20 psi.;

Run this procedureArrow right

1 Yearly Screw Chiller Maintenance

Check mark

Annual (or spring startup) operations include all weekly and monthly operations.

Check mark

General:

Check mark

- Inspect thermal insulation for integrity

Check mark

- Clean and paint as required

Check mark

Electrical ( * including the VFDs):

Check mark

- Sequence test controls

Check mark

- Check contactors for pitting, replace as required

Check mark

- Check terminals for tightness, tighten as necessary

Check mark

- Clean control panel interior

Run this procedureArrow right

Parts for Daikin Screw Chiller AWV022

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

AWG Wire Gauge

83754

AWG Wire

83804

Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166

H-EC01

Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217

Chlor*Rid DTS

AWG Wire Gauge

83754

AWG Wire

83804

Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166

H-EC01

Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217

Chlor*Rid DTS

AWG Wire Gauge

83754

AWG Wire

83804

Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166

H-EC01

Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217

Chlor*Rid DTS

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets