

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Screw Chiller AWV026
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3 Monthly Epoxy Coated Coils Cleaning
Warning: This cleaning procedure requires trained personnel with PPE!
Is the coil free of surface debris?
Select the cleaning agent used
If grease or oil film is present, it should be removed with the approved cleaning agent before applying CHLOR*RID DTS.
Was the entire coil surface thoroughly wetted with the cleaning agent?
After the substrate has been thoroughly wetted, the salts will be soluble and it is now only necessary to rinse them off.
Was the coil rinsed with a hose?
Warning: A pressure washer will damage the fins. The water used for the rinse is recommended to be of potable quality.
Was all cleaner residue thoroughly rinsed off?
Oil Sump Check
Enter the Discharge Temperature
Enter the Saturated Oil Temperature
Is Discharge Temperature > Saturated Oil Temperature + 5°C?
Is Discharge Temperature < Saturated Oil Temperature + 4.5°C?
Sign off on the oil sump check
Electrical Terminals Check
DANGER: Electric equipment can cause electric shock which will cause severe personal injury or death. Turn off, lock out and tag all power before continuing with following service. Panels can have more than one power source.
CAUTION: Periodically check electrical terminals for tightness and tighten as required. Always use a backup wrench when tightening electrical terminals.
Power turned off, locked out and tagged?
Electrical terminals checked for tightness
Backup wrench used when tightening electrical terminals
Sign off on the electrical terminals check
Screw Chiller Pre-Startup Inspection
NOTICE: Daikin Applied service personnel or factory authorized service agency must perform initial startup in order to activate warranty. Return the “Screw Compressor Equipment Warranty Form” within 10 working days to Daikin Applied as instructed on the form to obtain full warranty benefits.
CAUTION: Most relays and terminals in the unit control center are powered when S1 is closed and the control circuit disconnect is on. Therefore, do not close S1 until ready for startup or the unit may start unintentionally and possibly cause equipment damage.
Double check that the discharge shutoff valve and the optional compressor suction butterfly valves are open.
Check that the manual liquid line shutoff valves at the outlet of the subcooler coils are open.
Check the leaving chilled water temperature set point on the MicroTech® III controller to be sure it is set at the desired chilled water temperature.
Start the auxiliary equipment for the installation by turning on the time clock, and/or remote on/off switch, and chilled water pump.
Check to see that pumpdown switches Q1 and Q2 are in the “Pumpdown and Stop” (open) position. Throw the S1 switch to the “Auto” position.
Under the “Control Mode” menu of the keypad, place the unit into the automatic Cool Mode.
Start the system by moving pumpdown switch Q1 to the “Auto” position.
Screw Chiller Pre-Start Check
Chilled Water:
- Piping Complete
- Water strainer installed on evaporator, 0.125” (3.2mm) or smaller perforations
- Water System filled, flushed and vented
- Pumps installed and operational (rotation checked, strainers cleaned)
- Controls operational (3-way valves, face/bypass dampers, bypass valves, etc.)
- Water system operated and tested; flow meets unit design requirements
- Flow switch installed and wired
- Vent installed on evaporator
Access the parts list for your equipment in MaintainX.
AWG Wire Gauge
83754
AWG Wire
83804
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
AWG Wire Gauge
83754
AWG Wire
83804
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
AWG Wire Gauge
83754
AWG Wire
83804
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













