Daikin Packaged Heating and Cooling Unit DFG1804WL
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3 Monthly Air FIlter Replacement
WARNING! HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death
WARNING! To prevent personal injury or death due to improper installation, adjustment, alteration, service or maintenance, refer to this manual. For additional assistance or information, consult a qualified installer, servicer agency or the gas supplier
CAUTION! Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution
CAUTION! To prevent property damage due to fire and loss of equipment efficiency or equipment damage due to dust and lint build up on internal parts, never operate unit without an air filter installed in the return air system
1. Every application may require a different frequency of replacement of dirty filters
2. Filters must be replaced at least every three (3) months during operating seasons
3. Dirty filters are the most common cause of inadequate heating or cooling performance
4. Dirty throwaway filters should be discarded and replaced with a new, clean filter
5. Disposable return air filters are supplied with this unit. See the unit Specification Sheet or Technical Manual for the correct size and part number
Packaged Air Conditioner Maintenance
WARNING! HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death
WARNING! To prevent personal injury or death due to improper installation, adjustment, alteration, service or maintenance, refer to this manual. For additional assistance or information, consult a qualified installer, servicer agency or the gas supplier
CAUTION! Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution
CAUTION! To prevent property damage due to fire and loss of equipment efficiency or equipment damage due to dust and lint build up on internal parts, never operate unit without an air filter installed in the return air system
Lubrication
1. The supply fan motors, the condenser fan motors and compressors are permanently lubricated
Cabinet Finish Maintenance
1. Use a fine grade automotive wax on the cabinet finish to maintain the finish’s original high luster. This is especially important in installations with extended periods of direct sunlight
MicroChannel Heat Exchangers (MCHE) Maintenance
Packaged Air Conditioner Cleaning
WARNING! HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.
WARNING! To prevent personal injury or death due to improper installation, adjustment, alteration, service or maintenance, refer to this manual. For additional assistance or information, consult a qualified installer, servicer agency or the gas supplier.
CAUTION! Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution.
CAUTION! To prevent property damage due to fire and loss of equipment efficiency or equipment damage due to dust and lint build up on internal parts, never operate unit without an air filter installed in the return air system.
NOTE! During periods when the MCHE is not operated for longer than a week, the MCHE must be completely cleaned following the cleaning procedure. This practice must also be performed during short shut-down periods where corrosive deposits accumulate on the MCHE.
STEP 1: Remove Surface Debris
STEP 2: Rinse! Rinse the coil by following procedure
STEP 3: Dry
WARNING! Field applied coatings are not recommended for brazed aluminum MicroChannel heat exchangers. MicroChannel heat exchangers must NOT be coated using any other coating, Coating of a coil using a supplier or coating process is not approved and is not covered by the warranty. It may also reduce the lifetime and/or the performance of the MicroChannel heat exchanger.
2 Monthly Air FIlter Inspection
WARNING! HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.
WARNING! To prevent personal injury or death due to improper installation, adjustment, alteration, service or maintenance, refer to this manual. For additional assistance or information, consult a qualified installer, servicer agency or the gas supplier.
CAUTION! Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution.
CAUTION! To prevent property damage due to fire and loss of equipment efficiency or equipment damage due to dust and lint build up on internal parts, never operate unit without an air filter installed in the return air system.
Filter inspection should be made at least every two months; more often if necessary because of local conditions and usage.
Sign off on the air filter inspection
6 Monthly Air Conditioner Inspection
WARNING! HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death
WARNING! To prevent personal injury or death due to improper installation, adjustment, alteration, service or maintenance, refer to this manual. For additional assistance or information, consult a qualified installer, servicer agency or the gas supplier
CAUTION! Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution
NOTE! Preventive maintenance is the best way to avoid unnecessary expense and inconvenience. Have this system inspected at regular intervals by qualified service personnel, at least twice a year.
Tighten, set screws, and wire connections
Clean evaporator mechanically or with cold water, if necessary. Usually any fouling is only matted on the entering air face of the coil and can be removed by brushing
Replace filters as needed
Check for blockage of condensate drain
Check power and control voltages
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX