Daikin Outdoor Unit Air Conditioner RXTQ60TBVJUB
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Refrigerant Shortage Check
Warning: This check requires trained personnel with PPE!
Enter the superheating degree of suction gas
Is the compressor discharge gas temperature higher?
Does the electronic expansion valve turn open?
Does the low pressure drop?
Is the unit not demonstrating cooling/heating capacity?
Sign off on the refrigerant shortage check
Broken Wire Check
Warning: Ensure the power supply to all equipment is turned OFF before starting the procedure.
Power supply to all equipment turned OFF?
Short circuit between the indoor-outdoor unit terminal F1 and F2 in the outdoor unit.
Short circuit between the indoor-outdoor unit terminal F1 and F2 in the outdoor unit done?
Conduct continuity checks between the transmission wirings F1 and F2 of the indoor unit a that is farthest from the outdoor unit using a multimeter.
Continuity check between the transmission wirings F1 and F2 of the indoor unit a done?
Is there continuity between the said transmission wirings?
If there is no continuity, the transmission wiring may have broken wires. With the indoor-outdoor unit terminal of the outdoor unit short circuited, identify the place with continuity in the transmission wiring of the indoor unit b, transmission wiring of the indoor unit c, and transmission wiring of the indoor unit d in the order described.
Place with continuity in the transmission wiring of the indoor unit b identified?
Refrigerant Overcharge Check
Warning: This procedure requires trained personnel with PPE!
Enter the high pressure reading
Is overload control conducted causing insufficient cooling capacity?
Enter the superheating degree of suction gas
Is the compressor lower in discharge pipe temperature despite of pressure loads?
Enter the subcooling degree of condensate
In heating, is the temperature of discharge air through the subcooled section lower?
Sign off on the refrigerant overcharge check
Power Transistor Check
Warning: Power off the system before starting the procedure
Remove all the wiring connected to the PCB where power transistors are mounted on
Upload a photo of the PCB with removed wiring
Prepare a multimeter. An analog system is recommended, but a digital system with diode check function is also usable
Is the multimeter prepared?
Wait for 10 minutes after power OFF before proceeding
Has 10 minutes passed since power OFF?
Enter the resistance value measured using the multimeter
Sign off on the power transistor check
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX