MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Indoor Unit Cooling Only Air Conditioner FTN50JV1G9

Need answers fast?
Explore the manual using AI.

Daikin Indoor Unit Cooling Only Air Conditioner FTN50JV1G9
Daikin Indoor Unit Cooling Only Air Conditioner FTN50JV1G9

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Indoor Unit Cooling Only Air Conditioner FTN50JV1G9

Daikin Indoor Unit Cooling Only Air Conditioner FTN50JV1G9

Create an account to install this asset package.

Maintenance Plans for Daikin Indoor Unit Cooling Only Air Conditioner Model FTN50JV1G9

Integrate maintenance plans directly into your work orders in MaintainX.

Front Panel Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Open the front panel over the position where it stops.

Check mark

Slide the front panel to the right and release the left shaft.

Check mark

When reassembling the front panel, fit the right and left shafts one by one into the grooves and fully push them into position.

Check mark

Release the right shaft in the same way.

Check mark

Remove the front panel.

Check mark

Sign off on the front panel removal

Run this procedureArrow right

Fan Motor / Fan Rotor Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Remove the 2 screws.

Check mark

Lift and remove the right side plate.

Check mark

You can remove the fan rotor without detaching the right side plate.

Check mark

Remove the screw, and then the fan motor fixing plate.

Check mark

When reassembling the fan motor and the fan rotor, provide as much as 5 mm (0.2 inch) of play between the side face of the rotor and the bottom frame.

Check mark

Insert the fan motor allowing for approx. 5 mm (0.2 inch) of play.

Check mark

Tighten the fan rotor screw until it stops. Then give the screw one more turn.

Check mark

If the fan rotor rotates appropriately, tighten the screw completely.

Run this procedureArrow right

Front Grille Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Remove the 3 screws of the front grille.

Check mark

Unfasten the 3 hooks on the top of the front grille.

Check mark

The convex marks (...) on the front grille indicate the position of the hooks.

Check mark

When reassembling, make sure that the 3 hooks are securely fastened.

Check mark

Pull the upper part of the front grille out and lift the lower part up, and then remove the front grille.

Check mark

Sign off on the front grille removal

Run this procedureArrow right

Air Filter Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Open the front panel.

Check mark

Release each air filter from the 2 hooks of the front panel.

Check mark

Remove the air filter by pulling out downward.

Check mark

The air filter is not marked for difference between the right and left sides. Insert the air filter with the “FRONT” mark faced up. When reassembling, insert the air filter along the guides. Be sure to fasten the hooks when installing the air filter.

Check mark

Remove the Titanium apatite photocatalytic air-purifying filter, if available, from the 5 hooks.

Check mark

The right and left filters are interchangeable. Some models have no Titanium apatite photocatalytic air-purifying filter.

Check mark

Sign off on the air filter removal

Run this procedureArrow right

Vertical Blade ASSY Removal

Check mark

Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

1. For auto-swing (right and left) models

Check mark

Some models have fan guards. Remove the fan guards beforehand.

Check mark

The unit has 3 sets of vertical blade ASSYs linked to one another with interlock rods.

Check mark

1) Release the right and left shafts.

Check mark

2) Unfasten the 3 hooks for each set of vertical blade ASSY (9 hooks).

Check mark

3) Pull the vertical blade ASSYs to the right and remove them.

Check mark

2. For models without autoswing (right and left)

Check mark

Each vertical blade ASSY has 5 or 6 fins which can not be replaced individually.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets